| 1 | Zorbax C18 | Agilent Technologies | A | 1.08 | 0.0500 | 0.470 | 0.0600 | 1.48 | 1.56 | 10.7 | L1 | C18 |
| 2 | Zorbax C8 | Agilent Technologies | A | 0.970 | -0.0400 | 0.210 | 0.170 | 0.970 | 1.05 | 8.3 | L7 | C8 |
| 3 | Zorbax Eclipse XDB-C18 | Agilent Technologies | B | 1.07 | 0.0200 | -0.0600 | -0.0300 | 0.0500 | 0.0800 | 9.1 | L1 | C18 |
| 4 | Zorbax Eclipse XDB-C8 | Agilent Technologies | B | 0.910 | 0.0200 | -0.210 | 0 | 0 | 0.0100 | 6.6 | L7 | C8 |
| 5 | Zorbax Extend C18 | Agilent Technologies | B | 1.09 | 0.0500 | 0.0100 | -0.0400 | 0.0300 | 0.0100 | 8.4 | L1 | C18 |
| 6 | Zorbax Rx-18 | Agilent Technologies | B | 1.07 | 0.0300 | 0.300 | -0.0300 | 0.0900 | 0.410 | 7.7 | L1 | C18 |
| 7 | Zorbax Rx-C8 | Agilent Technologies | B | 0.790 | -0.0700 | 0.110 | 0.0100 | 0.0100 | 0.940 | 5 | L7 | C8 |
| 8 | Zorbax StableBond 300A C18 | Agilent Technologies | B | 0.900 | -0.0500 | 0.0400 | 0.0400 | 0.250 | 0.700 | 2.2 | L1 | C18 |
| 9 | Zorbax StableBond 300A C3 | Agilent Technologies | B | 0.520 | -0.120 | -0.190 | 0.0400 | 0.0500 | 0.350 | 0.7 | L56 | C3 |
| 10 | Zorbax StableBond 300A C8 | Agilent Technologies | B | 0.700 | -0.0800 | 0 | 0.0400 | 0.140 | 0.820 | 1.3 | L7 | C8 |
| 11 | Zorbax StableBond 80A C18 | Agilent Technologies | B | 0.990 | -0.0300 | 0.260 | 0 | 0.130 | 1.04 | 7.6 | L1 | C18 |
| 12 | Zorbax StableBond 80A C3 | Agilent Technologies | B | 0.600 | -0.120 | -0.0800 | 0.0300 | -0.0800 | 0.810 | 2.8 | L56 | C3 |
| 13 | Zorbax StableBond 80A C8 | Agilent Technologies | B | 0.790 | -0.0700 | 0.130 | 0.0100 | 0.0100 | 1.02 | 5.1 | L7 | C8 |
| 15 | Zorbax SB-AQ | Agilent Technologies | EP | 0.590 | -0.120 | -0.0800 | 0.0300 | -0.130 | 0.730 | 2.5 | | EP |
| 16 | Zorbax SB-Phenyl | Agilent Technologies | phenyl | 0.620 | -0.160 | 0.0600 | 0.0300 | 0.0300 | 1.08 | 2.7 | L11 | Phenyl |
| 17 | Zorbax XDB-Phenyl | Agilent Technologies | phenyl | 0.660 | -0.120 | -0.240 | 0.0100 | 0.0600 | 0.580 | 3.2 | L11 | Phenyl |
| 18 | Zorbax SB-CN | Agilent Technologies | CN | 0.500 | -0.100 | -0.220 | 0.0400 | -0.140 | 1.04 | 1.7 | L10 | CN |
| 19 | Zorbax Eclipse XDB-CN | Agilent Technologies | CN | 0.450 | -0.0600 | -0.310 | 0 | 0.0700 | 0.990 | 1.3 | L10 | CN |
| 20 | Kromasil 100 5 C18 | Kromasil by Nouryon | B | 1.05 | 0.0300 | -0.0700 | -0.0200 | 0.0300 | -0.0500 | 12.5 | L1 | C18 |
| 21 | Kromasil 100 5 C4 | Kromasil by Nouryon | B | 0.730 | 0 | -0.330 | 0.0100 | 0 | 0 | 5 | L26 | C4 |
| 22 | Kromasil 100 5 C8 | Kromasil by Nouryon | B | 0.860 | 0.0100 | -0.210 | 0.0100 | 0.0500 | 0 | 7.6 | L7 | C8 |
| 23 | Kromasil KR60 5 CN | Kromasil by Nouryon | CN | 0.440 | -0.130 | -0.570 | -0.0100 | 0.210 | 1.03 | 2 | L10 | CN |
| 24 | Adsorbosphere C18 | Grace/Alltech | A | 0.980 | -0.0700 | 0.0700 | -0.0400 | 1.49 | 1.68 | 7.7 | L1 | C18 |
| 25 | Adsorpbosphere UHS C18 | Grace/Alltech | B | 1.10 | 0 | 0.400 | -0.0400 | -0.120 | -0.120 | 18.2 | L1 | C18 |
| 26 | Allsphere ODS1 | Grace/Alltech | A | 0.730 | -0.160 | 0.380 | 0 | 0.840 | 1.14 | 4.7 | L1 | C18 |
| 27 | Allsphere ODS2 | Grace/Alltech | A | 1.00 | -0.0400 | 0.240 | -0.0200 | 0.960 | 1.28 | 8 | L1 | C18 |
| 28 | Alphabond (C18) | Grace/Alltech | A | 0.840 | -0.0900 | 0.0600 | 0 | 0.570 | 1.76 | 5.3 | L1 | C18 |
| 29 | Econosil C18 | Grace/Alltech | A | 0.960 | -0.0600 | 0.370 | -0.0300 | 1.02 | 1.33 | 8.2 | L1 | C18 |
| 30 | Econosphere C18 | Grace/Alltech | A | 0.810 | -0.120 | 0.0300 | -0.0100 | 1.04 | 1.52 | 5.1 | L1 | C18 |
| 31 | GraceSmart RP 18 5u | Grace/Alltech | B | 0.830 | -0.0300 | 0.0700 | 0 | 0.0700 | 0.740 | 4 | L1 | C18 |
| 32 | Alltima AQ | Grace/Alltech | B | 0.880 | -0.0700 | 0.300 | 0.0100 | 0.150 | 1.15 | 8.8 | | C18 |
| 33 | Alltima C18 | Grace/Alltech | B | 0.990 | -0.0100 | 0.0300 | -0.0100 | 0.0900 | 0.390 | 11.5 | L1 | C18 |
| 34 | Alltima C18-LL | Grace/Alltech | B | 0.780 | 0.0800 | -0.160 | 0.0400 | -0.0500 | 0.360 | 5.9 | L1 | C18 |
| 35 | Alltima C18-WP | Grace/Alltech | B | 0.930 | -0.0600 | 0.0200 | 0 | -0.0700 | -0.0800 | 4.9 | L1 | C18 |
| 36 | Alltima C8 | Grace/Alltech | B | 0.750 | 0.0100 | -0.270 | 0 | -0.0600 | 0.280 | 5.5 | L7 | C8 |
| 37 | Alltima HP C18 | Grace/Alltech | B | 0.980 | -0.0200 | -0.0400 | 0 | 0.170 | 0.190 | 4.9 | L1 | C18 |
| 38 | Alltima HP C18 High Load | Grace/Alltech | B | 1.08 | -0.0600 | 0.0600 | -0.0400 | -0.320 | -0.240 | 11.8 | L1 | C18 |
| 39 | Alltima HP C8 | Grace/Alltech | B | 0.830 | 0.0100 | -0.110 | 0.0300 | 0.120 | -0.410 | 3.1 | L7 | C8 |
| 40 | Brava BDS C18 | Grace/Alltech | B | 0.930 | -0.0300 | 0.0300 | 0.0100 | 0.280 | 0.760 | 4.7 | L1 | C18 |
| 41 | Platinum C18 | Grace/Alltech | A | 0.780 | -0.0700 | -0.0900 | 0 | 0.400 | 0.690 | 4.6 | L1 | C18 |
| 42 | Platinum C8 | Grace/Alltech | B | 0.580 | -0.0500 | -0.220 | 0 | 0.250 | 0.390 | 3 | L7 | C8 |
| 43 | Platinum EPS C18 | Grace/Alltech | A | 0.610 | -0.170 | 0.300 | 0.0200 | 0.680 | 1.70 | 2.6 | L1 | C18 |
| 44 | Platinum EPS C8 | Grace/Alltech | A | 0.420 | -0.150 | 0.150 | 0.0200 | 0.500 | 1.36 | 1.1 | L7 | C8 |
| 45 | Prevail C18 | Grace/Alltech | B | 0.880 | -0.0700 | 0.310 | 0.0200 | 0.100 | 1.20 | 9.4 | L1 | C18 |
| 46 | Prevail C8 | Grace/Alltech | B | 0.610 | -0.0800 | 0.0300 | 0.0400 | 0.0800 | 1.07 | 3.4 | L7 | C8 |
| 47 | Prevail Select C18 | Grace/Alltech | B | 0.820 | 0.0200 | -0.360 | 0.140 | -1.05 | 0.450 | 7.5 | L1 | C18 |
| 48 | Alltima HP C18 Amide | Grace/Alltech | EP | 0.490 | -0.0200 | 0.350 | 0.120 | -0.0100 | 0.920 | 4.8 | L60 | EP |
| 49 | Alltima HP C18 EPS | Grace/Alltech | EP | 0.650 | -0.100 | 0.400 | 0.0300 | 0.450 | 0.950 | 1.2 | L1 | EP |
| 50 | Platinum EPS C18 300 | Grace/Alltech | EP | 0.450 | -0.0500 | 0.370 | 0.0100 | 0.240 | 1.29 | 3.6 | | EP |
| 51 | Platinum EPS C8 300 | Grace/Alltech | EP | 0.580 | -0.110 | -0.130 | 0.0800 | 0.480 | 0.960 | 0.8 | | EP |
| 52 | Prevail Amide | Grace/Alltech | EP | 0.860 | -0.0600 | 0.250 | 0.0300 | 0.0500 | 1.20 | 9.6 | L60 | EP |
| 53 | Prosphere 300 C4 | Grace/Alltech | B | 0.680 | -0.0100 | -0.0500 | 0.0200 | 0.310 | 0.680 | 1 | L26 | C4 |
| 54 | Prosphere 100 C18 | Grace/Alltech | B | 0.880 | -0.0700 | 0.300 | 0.0100 | 0.180 | 1.51 | 6.4 | L1 | C18 |
| 55 | Advantage 300 | Analytical Sales & Services | A | 0.860 | 0 | 0.120 | 0.0200 | 0.590 | 1.11 | 1.7 | L1 | C18 |
| 56 | Advantage Armor C18 120A | Analytical Sales & Services | B | 0.960 | -0.0100 | -0.0700 | 0 | 0.0700 | 0.260 | 8.6 | L1 | C18 |
| 57 | Armor C18 3um | Analytical Sales & Services | B | 0.960 | -0.0100 | -0.0700 | 0 | 0.120 | 0.290 | 8.5 | L1 | C18 |
| 58 | Ultrasphere Octyl | Hichrom | B | 0.890 | 0.0100 | 0 | 0.0800 | 0.150 | 0.540 | 5.7 | L7 | C8 |
| 59 | Ultrasphere ODS | Hichrom | B | 1.08 | -0.0100 | 0.170 | 0.0600 | 0.270 | 0.380 | 8.7 | L1 | C18 |
| 60 | BAS MF-8954 | BioAnalytical Systems | A | 0.970 | -0.0600 | 0.180 | 0.0200 | 1.08 | 1.39 | 6.9 | L1 | C18 |
| 61 | EU Reference Column | Bischoff | B | 1.00 | 0 | 0.260 | 0 | 0.170 | 0.440 | 9.3 | L1 | C18 |
| 62 | ProntoSIL 120 C18 SH | Bischoff | B | 1.03 | 0.0100 | -0.100 | -0.0200 | 0.110 | 0.400 | 8.7 | L1 | C18 |
| 63 | ProntoSIL 120 C8 SH | Bischoff | B | 0.730 | -0.0600 | -0.0800 | 0.0100 | 0.0700 | 0.520 | 4.9 | L7 | C8 |
| 64 | ProntoSIL 120 C1 | Bischoff | B | 0.410 | -0.0700 | -0.0800 | 0.0200 | 0.0400 | 0.650 | 1.2 | C13 | C1 |
| 65 | ProntoSIL 120 C18 H | Bischoff | B | 1.00 | 0 | -0.100 | 0 | 0.120 | 0.150 | 9.7 | L1 | C18 |
| 66 | ProntoSIL 120 C18-AQ | Bischoff | B | 0.970 | 0 | -0.0800 | 0 | 0.130 | 0.220 | 8.1 | L1 | C18 |
| 67 | ProntoSIL 120-3-C30 | Bischoff | A | 0.910 | -0.130 | 0.570 | 0 | 0.500 | 1.78 | 6.9 | L62 | C30 |
| 68 | ProntoSIL 300 C30 EC | Bischoff | B | 0.920 | -0.0400 | -0.0100 | 0.0100 | 0.300 | 0.450 | 2.8 | L62 | C30 |
| 69 | ProntoSIL 200 C18 AQ | Bischoff | B | 0.970 | -0.0100 | -0.0500 | 0 | 0.120 | 0.280 | 6.3 | L1 | C18 |
| 70 | ProntoSIL 200 C8 SH | Bischoff | B | 0.760 | -0.0200 | -0.190 | 0.0200 | 0.120 | 0.230 | 2.7 | L7 | C8 |
| 71 | ProntoSIL 200 C18 H | Bischoff | B | 0.950 | 0 | -0.120 | 0.0100 | 0.160 | 0.210 | 4.8 | L1 | C18 |
| 72 | ProntoSIL 200 C30 | Bischoff | A | 0.900 | -0.0900 | 0.340 | 0 | 0.300 | 1.17 | 4.4 | L62 | C30 |
| 73 | ProntoSIL 200 C4 | Bischoff | B | 0.540 | -0.0600 | -0.220 | 0.0300 | 0.0800 | 0.510 | 1.3 | L26 | C4 |
| 74 | ProntoSIL 300 C8 SH | Bischoff | B | 0.730 | -0.0400 | -0.130 | 0.0200 | 0.150 | 0.400 | 1.8 | L7 | C8 |
| 75 | ProntoSIL 300-5-C18 H | Bischoff | B | 0.950 | -0.0100 | -0.0900 | 0.0100 | 0.230 | 0.240 | 3.2 | L1 | C18 |
| 76 | ProntoSIL 300 C30 | Bischoff | A | 0.890 | -0.100 | 0.320 | 0.0300 | 0.400 | 1.54 | 3 | L62 | C30 |
| 77 | ProntoSIL 300 C4 | Bischoff | B | 0.470 | -0.0900 | -0.0700 | 0.0500 | 0.110 | 0.780 | 0.6 | L26 | C4 |
| 78 | ProntoSIL 60 C8 SH | Bischoff | B | 0.920 | -0.0100 | 0.160 | -0.0100 | -0.310 | 1.00 | 8.4 | L7 | C8 |
| 79 | ProntoSIL 60 C18 H | Bischoff | B | 1.15 | 0.0400 | 0.0600 | -0.0700 | 0.100 | 0.260 | 12.2 | L1 | C18 |
| 80 | ProntoSIL 60 C4 | Bischoff | B | 0.680 | -0.0700 | 0.100 | 0 | -0.0500 | 1.20 | 4.1 | L26 | C4 |
| 81 | ProntoSIL CN | Bischoff | CN | 0.370 | -0.110 | -0.410 | -0.0200 | 0.160 | 0.660 | 0.9 | L10 | CN |
| 82 | ProntoSIL 120 CN EC | Bischoff | CN | 0.420 | -0.0500 | -0.320 | 0.0100 | 0.0100 | 0.760 | 1.2 | L10 | CN |
| 83 | ProntoSIL 120 C18 ace-EPS | Bischoff | EP | 0.770 | 0.0400 | -0.590 | 0.220 | -0.300 | 0.0400 | 8.3 | | EP |
| 84 | ProntoSIL 120 C18 AQplus | Bischoff | EP | 0.940 | -0.0100 | 0.210 | 0.0400 | -0.130 | 0.600 | 9.1 | | EP |
| 85 | ProntoSIL 120 C8 ace-EPS | Bischoff | EP | 0.530 | 0 | -0.850 | 0.210 | -0.280 | 0.0900 | 3.7 | | EP |
| 86 | ProntoSIL 200 C18 ace-EPS | Bischoff | EP | 0.760 | 0.0200 | -0.560 | 0.210 | 0.0200 | 0.140 | 4.7 | | EP |
| 87 | ProntoSIL 300 C18 ace-EPS | Bischoff | EP | 0.760 | 0.0200 | -0.570 | 0.210 | -0.0500 | 0.130 | 2.9 | | EP |
| 88 | ProntoSIL 120 Phenyl | Bischoff | phenyl | 0.560 | -0.150 | -0.200 | 0.0200 | 0.170 | 0.710 | 2.5 | L11 | Phenyl |
| 89 | ProntoSIL 60 Phenyl | Bischoff | phenyl | 0.700 | -0.190 | 0 | -0.0100 | 0.410 | 1.51 | 4.5 | L11 | Phenyl |
| 90 | ProntoSIL HyperSORB 120 ODS | Bischoff | A | 0.950 | -0.0600 | 0.0300 | -0.0200 | 0.790 | 1.31 | 5.2 | L1 | C18 |
| 91 | ProntoSIL SpheriBOND 80 ODS1 | Bischoff | A | 0.700 | -0.190 | 0.360 | 0.0100 | 1.45 | 2.40 | 3.8 | L1 | C18 |
| 92 | ProntoSIL SpheriBOND 80 ODS2 | Bischoff | A | 1.01 | -0.0200 | 0.150 | -0.0300 | 0.730 | 1.00 | 7.7 | L1 | C18 |
| 93 | Acclaim 120 C18 | Dionex | B | 1.03 | 0.0100 | -0.140 | -0.0200 | 0.0800 | 0 | 10.1 | L1 | C18 |
| 94 | Acclaim 120 C8 | Dionex | B | 0.850 | 0 | -0.270 | 0.0100 | 0.0800 | 0.0100 | 6 | L7 | C8 |
| 95 | Acclaim300 C18 | Dionex | B | 0.950 | -0.0100 | -0.170 | 0.0100 | 0.260 | 0.220 | 2.9 | L1 | C18 |
| 96 | Acclaim Polar Advantage | Dionex | EP | 0.850 | -0.0600 | -0.110 | 0.0200 | -0.270 | 0.350 | 6.8 | L60 | EP |
| 97 | Acclaim Organic Acid | Dionex | other | 0.830 | -0.0600 | -0.380 | 0 | -0.310 | 0.340 | 6.7 | | Other |
| 98 | Acclaim PolarAdvantage II | Dionex | EP | 0.740 | 0.0100 | -0.550 | 0.210 | -0.220 | 0.670 | 6.3 | L60 | EP |
| 99 | SynChropak RP8 | Eprogen | A | 0.630 | -0.0900 | 0.100 | 0.0200 | 0.220 | 0.940 | 1.2 | L7 | C8 |
| 100 | SynChropak RPP | no longer available | A | 0.740 | -0.110 | 0.230 | 0.0300 | 0.250 | 1.28 | 1.8 | L1 | C18 |
| 101 | SynChropak RPP 100 | no longer available | A | 0.910 | -0.0500 | -0.0700 | 0.120 | 0.220 | 0.310 | 5.4 | L1 | C18 |
| 102 | Chromegabond WR C18 | ES Industries | B | 0.970 | 0.0200 | -0.150 | 0 | 0.320 | 0.280 | 5.4 | L1 | C18 |
| 103 | Chromegabond WR C8 | ES Industries | B | 0.850 | 0.0200 | -0.270 | 0.0200 | 0.200 | 0.140 | 3.6 | L7 | C8 |
| 104 | Inertsil Ph-3 | GL Sciences | phenyl | 0.520 | -0.170 | -0.130 | 0.0400 | 0.120 | 0.730 | 2.6 | L11 | Phenyl |
| 105 | Inertsil C8-3 | GL Sciences | B | 0.830 | 0 | -0.260 | -0.0100 | -0.330 | -0.360 | 7.1 | L7 | C8 |
| 106 | Inertsil ODS-2 | GL Sciences | B | 1.00 | 0.0400 | -0.0700 | -0.0100 | -0.130 | 0.440 | 8.2 | L1 | C18 |
| 107 | Inertsil ODS-3 | GL Sciences | B | 0.990 | 0.0200 | -0.140 | -0.0200 | -0.470 | -0.330 | 10.9 | L1 | C18 |
| 108 | Inertsil ODS-P | GL Sciences | B | 0.970 | -0.0200 | 0.610 | -0.0300 | 0.230 | 1.47 | 11.2 | L1 | C18 |
| 109 | Inertsil WP300 C18 | GL Sciences | B | 0.930 | -0.0100 | -0.110 | 0 | 0.200 | 0.160 | 3.8 | L1 | C18 |
| 110 | Inertsil WP300 C8 | GL Sciences | B | 0.790 | -0.0100 | -0.210 | 0.0100 | 0.120 | 0.0600 | 2.2 | L7 | C8 |
| 111 | Inertsil CN-3 | GL Sciences | CN | 0.360 | 0.0400 | -0.800 | 0.0800 | -2.60 | -1.29 | 1.1 | L10 | CN |
| 112 | Inertsil ODS-EP | GL Sciences | EP | 0.800 | 0.0600 | -1.52 | 0.0500 | -0.620 | -0.0700 | 7.2 | L60 | C18 |
| 113 | Vydac 201TP | Grace/Vydac | A | 0.900 | -0.0200 | 0.400 | 0 | 0.390 | 1.02 | 2.1 | L1 | C18 |
| 114 | Vydac 218TP | Grace/Vydac | B | 0.900 | 0 | 0.340 | 0 | 0.270 | 0.670 | 2 | L1 | C18 |
| 115 | Vydac Everest | Grace/Vydac | B | 0.990 | 0.0400 | 0.120 | 0 | 0.0600 | 0.340 | 2.2 | L1 | C18 |
| 116 | Denali 120A C18 | Grace/Vydac | B | 1.05 | 0.0400 | 0.120 | -0.0100 | 0.140 | 0.220 | 9.4 | L1 | C18 |
| 117 | Vydac 218MS | Grace/Vydac | A | 0.770 | 0.180 | 0.110 | -0.370 | 0.650 | 1.23 | 1.7 | L1 | C18 |
| 119 | GROM-SIL 120 ODS-5 ST | Grace/Grom | B | 1.03 | 0 | 0.130 | 0 | 0.130 | 0.120 | 10.5 | L1 | C18 |
| 120 | GROM-SIL 120 Octyl-6 MB | Grace/Grom | B | 0.870 | 0 | 0 | 0.0200 | -0.0100 | 0.130 | 5.8 | L7 | C8 |
| 121 | GROM Saphire 110 C18 | Grace/Grom | B | 1.05 | 0 | 0.0800 | 0 | -0.0300 | 0.110 | 12.1 | L1 | C18 |
| 122 | GROM-SIL 120 ODS-3 CP | Grace/Grom | B | 1.02 | 0.0100 | 0.0900 | 0 | 0.0900 | 0.120 | 10.2 | L1 | C18 |
| 123 | GROM Saphire 110 C8 | Grace/Grom | B | 0.830 | -0.0300 | -0.100 | 0.0300 | -0.0900 | 0.250 | 7.1 | L7 | C8 |
| 124 | HxSil C18 | Hamilton | B | 0.840 | -0.0700 | 0.300 | 0.0100 | 0.230 | 1.05 | 7 | L1 | C18 |
| 125 | HxSil C8 | Hamilton | B | 0.680 | -0.0700 | 0.0800 | 0.0300 | 0.0600 | 0.850 | 4.4 | L7 | C8 |
| 126 | Hichrom RPB | Hichrom | B | 0.960 | 0.0200 | 0.100 | 0 | 0.150 | 0.140 | 6.4 | L1 | C18 |
| 127 | Hichrom 300 5 RPB | Hichrom | B | 0.940 | 0.0200 | 0.0400 | 0.0100 | 0.220 | 0.210 | 2.6 | L1 | C18 |
| 128 | Targa C18 | Higgins Analytical | B | 0.970 | -0.0100 | -0.0700 | 0 | 0.0100 | 0.170 | 8.6 | L1 | C18 |
| 129 | Unison UK-C18 | Imtakt | B | 0.980 | -0.0100 | 0.0100 | -0.0100 | 0.110 | 0.0700 | 8.9 | L1 | C18 |
| 130 | Apex C18 | Grace/Jones | A | 0.980 | -0.0300 | 0.0100 | 0.0400 | 1.24 | 2.31 | 6.1 | L1 | C18 |
| 131 | Apex C8 | Grace/Jones | A | 0.860 | -0.0700 | 0.230 | 0.170 | 1.36 | 1.37 | 4.4 | L1 | C18 |
| 132 | Apex II C18 | Grace/Jones | A | 1.00 | -0.0700 | 0.230 | 0.120 | 2.03 | 2.69 | 6.7 | L1 | C18 |
| 133 | Genesis AQ 120A | Grace/Jones | B | 0.960 | -0.0300 | -0.150 | 0 | 0.0600 | 0.230 | 9.6 | L1 | C18 |
| 134 | Genesis C18 120A | Grace/Jones | B | 1.00 | 0 | -0.0600 | 0 | 0.130 | 0.120 | 9.8 | L1 | C18 |
| 135 | Genesis C18 300A | Grace/Jones | B | 0.970 | 0 | -0.0800 | 0.0100 | 0.260 | 0.270 | 3.5 | L1 | C18 |
| 136 | Genesis C4 300A | Grace/Jones | B | 0.610 | -0.0500 | -0.390 | 0.0300 | 0.140 | 0.240 | 1.1 | L26 | C4 |
| 137 | Genesis C4 EC 120A | Grace/Jones | B | 0.640 | -0.0500 | -0.330 | 0.0200 | 0.0600 | 0.400 | 3.4 | L26 | C4 |
| 138 | Genesis C8 120A | Grace/Jones | B | 0.820 | -0.0100 | -0.0800 | 0.0100 | 0.0500 | 0.300 | 6.2 | L7 | C8 |
| 139 | Genesis EC C8 120A | Grace/Jones | B | 0.860 | 0 | -0.170 | 0.0200 | 0.0600 | 0.140 | 6.9 | L7 | C8 |
| 140 | Genesis CN 120A | Grace/Jones | CN | 0.420 | -0.110 | -0.680 | -0.0100 | 0 | 0.570 | 1.4 | L10 | CN |
| 141 | Genesis CN 300A | Grace/Jones | CN | 0.390 | -0.100 | -0.640 | 0 | 0.0200 | 0.390 | 0.5 | L10 | CN |
| 142 | Genesis Phenyl | Grace/Jones | phenyl | 0.600 | -0.140 | -0.360 | 0.0300 | 0.130 | 0.580 | 2.9 | L11 | Phenyl |
| 143 | Nucelosil 100-5-C8 HD | Macherey Nagel | A | 0.860 | 0 | -0.170 | 0.0200 | 0.0400 | 0.180 | 6.3 | L7 | C8 |
| 144 | Nucleosil 100 5 C18 HD | Macherey Nagel | A | 0.960 | -0.0200 | -0.120 | 0 | 0.0800 | 0.150 | 8.8 | L1 | C18 |
| 145 | Nucleosil 100 5 C18 Nautilus | Macherey Nagel | EP | 0.700 | 0 | -0.480 | 0.260 | -0.440 | 0.480 | 5.4 | L60 | EP |
| 146 | Nucleosil C8 | Macherey Nagel | A | 0.570 | -0.130 | 0.0300 | 0.0100 | 0.280 | 1.12 | 2.7 | L7 | C8 |
| 147 | Nucleosil C18 | Macherey Nagel | A | 0.900 | -0.0500 | 0.0100 | -0.0300 | 0.320 | 0.730 | 7.3 | L1 | C18 |
| 148 | Nucleosil 300 5 C18 | Macherey Nagel | A | 0.860 | -0.0800 | 0 | 0.0100 | 0.450 | 0.980 | 2.7 | L1 | C18 |
| 149 | Nucleodur C8 Gravity 5 micron | Macherey Nagel | B | 0.860 | 0.0300 | -0.240 | 0 | -0.150 | 0.630 | 6.6 | L1 | C18 |
| 150 | Nucleodur C18 Gravity | Macherey Nagel | B | 1.05 | 0.0400 | -0.0900 | -0.0200 | -0.0800 | 0.310 | 11 | L1 | C18 |
| 151 | EC Nucleosil 100-5 Protect 1 | Macherey Nagel | EP | 0.540 | 0.0400 | -0.410 | 0.300 | -3.21 | -0.570 | 2.7 | | EP |
| 152 | ACE 5 C8-300 | ACT | B | 0.780 | 0 | -0.110 | 0.0300 | 0.140 | 0.380 | 1.8 | L7 | C8 |
| 153 | ACE 5 C4 | ACT | B | 0.670 | -0.0100 | -0.170 | 0.0200 | 0.0900 | 0.310 | 2.5 | L26 | C4 |
| 154 | ACE 5 C4-300 | ACT | B | 0.710 | -0.0100 | -0.180 | 0.0300 | 0.160 | 0.350 | 1.3 | L26 | C4 |
| 155 | ACE 5 C18 | ACT | B | 1.00 | 0.0200 | -0.0900 | 0 | 0.140 | 0.0900 | 7.9 | L1 | C18 |
| 156 | ACE 5 C18-300 | ACT | B | 0.980 | 0.0200 | 0.0400 | 0.0100 | 0.260 | 0.230 | 3 | L1 | C18 |
| 157 | ACE 5 C8 | ACT | B | 0.827 | 0.00500 | -0.180 | 0.0260 | 0.110 | 0.160 | 4.9 | L7 | C8 |
| 158 | ACE 5 CN | ACT | CN | 0.400 | -0.100 | -0.720 | 0 | -0.0800 | 0.440 | 1 | L10 | CN |
| 159 | ACE 5 CN-300 | ACT | CN | 0.460 | -0.0700 | -0.160 | 0.0300 | 0.150 | 0.850 | 0.4 | L10 | CN |
| 160 | ACE 5 AQ | ACT | EP | 0.800 | -0.0500 | -0.120 | 0.0300 | 0 | 0.160 | 4.7 | | EP |
| 161 | ACE 5 Phenyl | ACT | phenyl | 0.640 | -0.130 | -0.290 | 0.0200 | 0.130 | 0.460 | 2.8 | L11 | Phenyl |
| 162 | ACE Phenyl-300 | ACT | phenyl | 0.590 | -0.100 | -0.230 | 0.0300 | 0.160 | 0.540 | 1.1 | L11 | Phenyl |
| 163 | Precision CN | Mac-Mod Analytical | CN | 0.430 | -0.110 | -0.480 | 0.0100 | -0.0400 | 0.600 | 1.3 | L10 | CN |
| 164 | Precision C18 | Mac-Mod Analytical | B | 1.00 | 0 | -0.0400 | -0.0100 | 0.0700 | 0.340 | 9.5 | L1 | C18 |
| 165 | Precision C8 | Mac-Mod Analytical | B | 0.820 | -0.0100 | -0.180 | 0.0200 | 0.0900 | 0.240 | 4.9 | L7 | C8 |
| 166 | Precision C18-PE | Mac-Mod Analytical | EP | 0.970 | -0.0100 | -0.0800 | 0 | 0 | 0.160 | 8.6 | L1 | EP |
| 167 | Precision C8-PE | Mac-Mod Analytical | EP | 0.810 | -0.0200 | -0.150 | 0.0100 | 0.0500 | 0.270 | 5 | L7 | EP |
| 168 | Precision Phenyl | Mac-Mod Analytical | phenyl | 0.590 | -0.130 | -0.290 | 0.0200 | 0.0900 | 0.500 | 2.6 | L11 | Phenyl |
| 169 | LiChrosorb RP-18 | Merck KGaA (EMD Millipore)Ê | A | 0.900 | -0.0700 | 0.150 | -0.0800 | 0.710 | 0.970 | 7.1 | L1 | C18 |
| 170 | LiChrospher 100 RP-18 | Merck KGaA (EMD Millipore)Ê | A | 1.00 | -0.0200 | 0.180 | -0.0300 | 0.640 | 0.890 | 9.5 | L1 | C18 |
| 171 | Chromolith RP18e | Merck KGaA (EMD Millipore)Ê | B | 1.00 | 0.0200 | 0 | -0.0100 | 0.100 | 0.180 | 3.1 | L1 | C18 |
| 172 | LiChrospher 60 RP-Select B | Merck KGaA (EMD Millipore)Ê | B | 0.740 | -0.0600 | -0.0400 | 0 | 0.100 | 0.860 | 5.1 | L1 | C8 |
| 173 | Purospher RP-18 | Merck KGaA (EMD Millipore)Ê | B | 0.840 | 0.230 | 0.150 | 0.300 | -0.960 | 0.900 | 4.9 | L1 | C18 |
| 174 | Purospher STAR RP18e | Merck KGaA (EMD Millipore)Ê | B | 1.00 | 0.0100 | -0.0700 | -0.0300 | 0.0100 | 0.0400 | 10.6 | L1 | C18 |
| 175 | Superspher 100 RP-18e | Merck KGaA (EMD Millipore)Ê | B | 1.03 | 0.0200 | -0.0200 | -0.0100 | 0.350 | 0.260 | 9.3 | L1 | C18 |
| 176 | COSMOSIL C18-AR-II | Nacalai Tesque | B | 1.01 | 0.0100 | 0.120 | -0.0200 | 0.110 | 0.490 | 8.1 | L1 | C18 |
| 177 | COSMOSIL C18-MS-II | Nacalai Tesque | B | 1.03 | 0.0400 | -0.130 | -0.0100 | -0.110 | -0.0200 | 8.1 | L1 | C18 |
| 178 | COSMOSIL 5-C18-PAQ | Nacalai Tesque | EP | 0.820 | -0.0200 | -0.340 | 0.0500 | -0.350 | 0.0400 | 5.5 | | EP |
| 179 | Develosil C30-UG-5 | Nomura | B | 0.970 | -0.0300 | -0.190 | 0.0100 | 0.150 | 0.170 | 7.8 | L62 | C30 |
| 180 | Develosil ODS-HG-5 | Nomura | B | 0.980 | 0.0100 | -0.170 | 0 | 0.180 | 0.220 | 8.2 | L1 | C18 |
| 181 | Develosil ODS-MG-5 | Nomura | B | 0.960 | -0.0300 | -0.160 | 0 | -0.0100 | 0.0500 | 11.2 | L1 | C18 |
| 182 | Develosil ODS-UG-5 | Nomura | B | 0.990 | 0.0200 | -0.140 | 0 | 0.150 | 0.150 | 8.4 | L1 | C18 |
| 183 | Bondclone C18 | Phenomenex | B | 0.820 | -0.0500 | -0.120 | 0.0400 | 0.0700 | 0.340 | 4.5 | L1 | C18 |
| 184 | Partisil C8 | Phenomenex | B | 0.740 | -0.0700 | -0.0900 | 0.0700 | 0.0300 | 0.540 | 4.5 | L7 | C8 |
| 185 | Partisil ODS(3) | Phenomenex | A | 0.810 | -0.0700 | 0 | 0 | 0.310 | 0.900 | 5.4 | L1 | C18 |
| 186 | Sphereclone ODS(2) | Phenomenex | A | 0.970 | -0.0400 | 0.270 | -0.0500 | 0.860 | 1.32 | 7.6 | L1 | C18 |
| 187 | Jupiter 300 C18 | Phenomenex | B | 0.940 | 0.0300 | -0.220 | 0 | 0.230 | 0.210 | 2.9 | L1 | C18 |
| 188 | Jupiter 300 C4 | Phenomenex | B | 0.690 | 0 | -0.420 | 0.0100 | 0.150 | 0.140 | 1.3 | L26 | C4 |
| 189 | Jupiter 300 C5 | Phenomenex | B | 0.720 | 0.0200 | -0.380 | 0.0100 | 0.120 | 0.330 | 1.5 | | C5 |
| 190 | Luna C18 | Phenomenex | B | 1.01 | 0.0200 | 0.0700 | 0 | -0.360 | -0.0300 | 10.9 | L1 | C18 |
| 191 | Luna C18(2) | Phenomenex | B | 1.00 | 0.0200 | -0.120 | 0 | -0.260 | -0.170 | 9.6 | L1 | C18 |
| 192 | Luna C5 | Phenomenex | B | 0.800 | 0.0300 | -0.250 | 0 | -0.270 | 0.110 | 5.9 | | C5 |
| 193 | Luna C8 | Phenomenex | B | 0.870 | 0.0300 | -0.0100 | 0.0200 | -0.400 | 0.130 | 7 | L7 | C8 |
| 194 | Luna C8(2) | Phenomenex | B | 0.880 | 0.0400 | -0.220 | 0 | -0.300 | -0.170 | 7.2 | L7 | C8 |
| 195 | Prodigy ODS(2) | Phenomenex | B | 0.990 | 0.0300 | -0.110 | 0 | -0.0900 | 0.230 | 7.7 | L1 | C18 |
| 196 | Prodigy ODS(3) | Phenomenex | B | 1.02 | 0.0200 | -0.130 | -0.0100 | -0.190 | -0.130 | 10.1 | L1 | C18 |
| 197 | Selectosil C18 | Phenomenex | B | 0.910 | -0.0500 | 0.0300 | 0 | 0.290 | 0.740 | 7 | L1 | C18 |
| 198 | Synergi Max-RP | Phenomenex | B | 0.980 | 0.0200 | 0 | -0.0100 | -0.130 | -0.0300 | 9.5 | L1 | C18 |
| 199 | Ultracarb ODS (30) | Phenomenex | B | 1.11 | 0.0100 | 0.370 | -0.0500 | -0.310 | 0.730 | 18.2 | L62 | C18 |
| 200 | Aqua C18 | Phenomenex | B | 0.960 | -0.0300 | 0.0300 | 0 | 0.0600 | 0.270 | 8.8 | L1 | C18 |
| 201 | Luna CN | Phenomenex | CN | 0.450 | -0.110 | -0.320 | -0.0200 | 0.430 | 1.32 | 1.3 | L10 | CN |
| 202 | Polaris C18-Ether | Agilent Technologies/Varian | EP | 0.940 | -0.0100 | -0.120 | 0.0200 | 0.160 | 0.550 | 5.5 | | EP |
| 203 | Polaris C8-Ether | Agilent Technologies/Varian | EP | 0.700 | -0.0200 | -0.310 | 0.0400 | 0.0900 | 0.260 | 1.8 | | EP |
| 204 | Synergi Hydro-RP | Phenomenex | EP | 1.02 | 0 | 0.160 | -0.0400 | -0.0700 | 0.260 | 11.3 | L1 | EP |
| 205 | Synergi Polar-RP | Phenomenex | EP | 0.650 | -0.140 | -0.250 | 0 | 0.0500 | 0.770 | 3.9 | L1 | EP |
| 206 | Luna Phenyl-Hexyl | Phenomenex | phenyl | 0.780 | -0.110 | -0.270 | 0 | 0 | 0.380 | 5.2 | L11 | Phenyl |
| 207 | Prodigy Phenyl-3 | Phenomenex | phenyl | 0.520 | -0.190 | 0.0500 | 0.0200 | 0.230 | 1.46 | 2.3 | L11 | Phenyl |
| 208 | Curosil-PFP | Phenomenex | F | 0.690 | -0.0700 | -0.260 | 0 | 0.110 | 0.370 | 4 | L43 | F |
| 209 | Onyx Monolithic C8 | Phenomenex | B | 0.820 | 0 | 0 | 0 | -0.0200 | 0.440 | 2 | L7 | C8 |
| 210 | Onyx Monolithic C18 | Phenomenex | B | 1.01 | 0.0200 | 0.220 | -0.0100 | 0.120 | 0.430 | 3.2 | L1 | C18 |
| 211 | Gemini C18 110A | Phenomenex | B | 0.960 | 0 | 0.0200 | 0.0100 | -0.0900 | 0.190 | 8 | L1 | C18 |
| 212 | Synergi Fusion-RP | Phenomenex | EP | 0.870 | -0.0300 | -0.0100 | 0 | -0.230 | 0.360 | 7.5 | | EP |
| 214 | Allure C18 | Restek | B | 1.13 | 0.0500 | 0.0400 | -0.0400 | -0.0300 | 0.0200 | 17.9 | L1 | C18 |
| 215 | Ultra C18 | Restek | B | 1.05 | 0.0300 | -0.0300 | -0.0200 | 0.0500 | 0 | 12.2 | L1 | C18 |
| 216 | Ultra C8 | Restek | B | 0.870 | 0.0100 | -0.190 | 0.0100 | -0.0300 | -0.0700 | 8.2 | L7 | C8 |
| 218 | Allure PFP Propyl | Restek | F | 0.830 | -0.260 | 0.0500 | 0.340 | 1.10 | 1.65 | 7.4 | L43 | F |
| 220 | UltraSep ES AMID H RP18P | SEPSERV | EP | 0.750 | -0.0100 | -0.100 | 0.250 | -0.520 | 0.850 | 4.9 | | EP |
| 221 | UltraSep ES PHARM RP18 | SEPSERV | A | 0.950 | -0.0600 | 0.430 | -0.0500 | 0.590 | 1.67 | 8.5 | L1 | C18 |
| 222 | Exsil C8 | no longer available | A | 0.750 | -0.0700 | -0.0400 | -0.0100 | 0.470 | 0.970 | 4.7 | L7 | C8 |
| 223 | Exsil ODS | no longer available | A | 0.990 | -0.0300 | 0.290 | -0.0400 | 0.830 | 1.22 | 7.6 | L1 | C18 |
| 224 | Wakosil 5 C8 RS | no longer available | B | 0.800 | 0 | -0.270 | 0 | -0.110 | 0.0900 | 5.6 | L7 | C8 |
| 225 | Wakosil II 5 C18 AR | no longer available | B | 0.990 | 0.0700 | -0.0500 | -0.0300 | 0.0700 | 0.0100 | 6.2 | L1 | C18 |
| 226 | Wakosil II 5 C18 HG | no longer available | B | 1.03 | 0.0300 | 0.0100 | -0.0200 | 0 | 0.210 | 7.1 | L1 | C18 |
| 227 | Wakosil II 5 C18 RS | no longer available | B | 0.960 | 0 | -0.160 | 0 | -0.0700 | 0.0400 | 9.2 | L1 | C18 |
| 228 | CAPCELL C18 UG120 | Shiseido | B | 1.00 | 0.0300 | 0.0300 | -0.0100 | 0.0100 | 0 | 6.9 | L1 | C18 |
| 229 | CAPCELL C18 AG120 | Shiseido | A | 1.03 | 0.0600 | 0.120 | -0.0600 | 0.540 | 0.620 | 7.2 | L1 | C18 |
| 230 | CAPCELL C18 MG | Shiseido | B | 1.00 | 0.0100 | 0.0400 | 0 | 0.0700 | 0 | 10.2 | L1 | C18 |
| 231 | CAPCELL C18 SG120 | Shiseido | B | 0.980 | 0.0300 | 0.0900 | -0.0200 | 0.120 | 0.190 | 6.6 | L1 | C18 |
| 232 | CAPCELL C18 AQ | Shiseido | EP | 0.860 | -0.0400 | -0.0600 | 0.0100 | -0.0900 | 0.400 | 7 | L1 | EP |
| 233 | CAPCELL C18 ACR | Shiseido | B | 1.02 | 0.0400 | 0.0700 | -0.0100 | 0.0300 | 0.110 | 8.5 | L1 | C18 |
| 234 | CAPCELL PAK C8 DD | Shiseido | B | 0.830 | 0.0200 | -0.150 | 0.0100 | -0.110 | -0.0700 | 5.4 | L7 | C8 |
| 235 | Capcell Pak C18 MGII | Shiseido | B | 1.01 | 0.0100 | 0.0400 | 0 | 0 | 0 | 9.9 | L1 | C18 |
| 236 | CAPCELL PAK C8 UG120 | Shiseido | B | 0.850 | 0.0300 | -0.0900 | -0.0100 | -0.0400 | -0.0100 | 4.3 | L7 | C8 |
| 238 | Discovery BIO Wide pore C18 | Supelco | B | 0.830 | 0.0100 | -0.250 | 0.0200 | 0.120 | 0.110 | 3.4 | L1 | C18 |
| 239 | Discovery BIO Wide pore C5 | Supelco | B | 0.650 | -0.0100 | -0.300 | 0.0200 | 0.0900 | 0.210 | 1.1 | | C5 |
| 240 | Discovery BIO Wide pore C8 | Supelco | B | 0.830 | 0.0100 | -0.220 | 0.0300 | 0.200 | 0.190 | 2.2 | L7 | C8 |
| 241 | Discovery C18 | Supelco | B | 0.980 | 0.0200 | -0.120 | 0 | 0.170 | 0.150 | 4.8 | L1 | C18 |
| 242 | Discovery C8 | Supelco | B | 0.830 | 0.0100 | -0.230 | 0.0200 | 0.110 | 0.140 | 3.3 | L7 | C8 |
| 243 | Discovery CN | Supelco | CN | 0.390 | -0.110 | -0.610 | 0 | -0.0300 | 0.510 | 0.6 | L10 | CN |
| 244 | Discovery Amide C16 | Supelco | EP | 0.720 | 0.0100 | -0.620 | 0.210 | -0.0900 | -0.0200 | 4 | L60 | EP |
| 245 | Discovery HS PEG | Supelco | EP | 0.310 | 0.0200 | -0.710 | 0.120 | -0.530 | 0.380 | 0.7 | | EP |
| 246 | Supelcosil LC-18 | Supelco | A | 1.01 | -0.0400 | 0.180 | 0.160 | 1.59 | 1.75 | 5.9 | L1 | C18 |
| 247 | Supelcosil LC-18-DB | Supelco | A | 0.970 | -0.0200 | 0.0400 | 0.110 | 0.480 | 0.530 | 5.7 | L1 | C18 |
| 248 | Supelcosil LC-8 | Supelco | A | 0.830 | -0.0400 | -0.0200 | 0.0800 | 1.11 | 1.09 | 3.6 | L7 | C8 |
| 249 | Supelcosil LC-8-DB | Supelco | A | 0.810 | -0.0300 | -0.0700 | 0.140 | 0.440 | 0.550 | 3.4 | L7 | C8 |
| 250 | Supelcosil LC-PAH | Supelco | A | 0.850 | -0.0200 | 0.100 | -0.0300 | 0.640 | 0.830 | 4.4 | L1 | C18 |
| 252 | Thermo CN | Thermo/Hypersil | CN | 0.400 | -0.110 | -0.700 | 0 | -0.0200 | 0.490 | 0.8 | L10 | CN |
| 253 | Hypersil 100 C18 | Thermo/Hypersil | A | 1.04 | 0.0200 | 0.110 | 0.0300 | 0.400 | 0.340 | 7.9 | L1 | C18 |
| 254 | Hypersil BDS C18 | Thermo/Hypersil | A | 0.990 | 0.0100 | -0.0900 | 0 | 0.330 | 0.280 | 5.6 | L1 | C18 |
| 255 | Hypersil Elite | no longer available | A | 0.950 | 0.0300 | 0.150 | -0.0100 | 0.310 | 0.730 | 6.5 | L1 | C18 |
| 256 | Hypersil ODS | Thermo/Hypersil | A | 0.970 | -0.0200 | -0.120 | 0.0200 | 0.910 | 0.970 | 5.5 | L1 | C18 |
| 257 | Hypersil ODS-2 | Thermo/Hypersil | B | 0.980 | 0.0100 | 0.130 | -0.0100 | 0.250 | 0.370 | 5.6 | L1 | C18 |
| 258 | Hypersil PAH | Thermo/Hypersil | A | 0.940 | -0.0500 | 0.230 | -0.0100 | 1.43 | 1.72 | 5.3 | L1 | C18 |
| 259 | Hypersil Beta Basic-18 | Thermo/Hypersil | B | 0.990 | 0.0300 | -0.0900 | 0 | 0.160 | 0.120 | 6.4 | L1 | C18 |
| 260 | Hypersil Beta Basic-8 | Thermo/Hypersil | B | 0.830 | 0.0100 | -0.240 | 0.0200 | 0.110 | 0.110 | 4.2 | L7 | C8 |
| 261 | Hypersil Betamax Neutral | Thermo/Hypersil | B | 1.09 | 0.0300 | 0.0600 | -0.0300 | -0.0300 | 0.0100 | 17 | L1 | C18 |
| 262 | BetaBasic CN | Thermo/Hypersil | CN | 0.420 | -0.0400 | -0.450 | 0.0100 | 0.0100 | 0.900 | 0.8 | L10 | CN |
| 263 | BetaMax Acid | Thermo/Hypersil | EP | 0.630 | 0.0500 | -0.590 | 0.370 | -2.06 | -0.510 | 5.8 | | EP |
| 264 | BetaMax Base | Thermo/Hypersil | EP | 0.470 | -0.0600 | -0.390 | 0.0100 | 0.0100 | 1.14 | 2.2 | | EP |
| 265 | Hypersil Bio Basic-18 | Thermo/Hypersil | B | 0.970 | 0.0200 | -0.100 | 0 | 0.250 | 0.210 | 3.2 | L1 | C18 |
| 266 | Hypersil Bio Basic-8 | Thermo/Hypersil | B | 0.820 | 0.0100 | -0.230 | 0.0200 | 0.230 | 0.210 | 1.8 | L7 | C8 |
| 267 | Hypersil GOLD | Thermo/Hypersil | B | 0.880 | 0 | -0.0100 | 0.0300 | 0.160 | 0.470 | 3.9 | L1 | C18 |
| 268 | Hypurity C18 | Thermo/Hypersil | B | 0.980 | 0.0200 | -0.0900 | 0 | 0.190 | 0.160 | 5.6 | L1 | C18 |
| 269 | HyPurity C4 | Thermo/Hypersil | B | 0.710 | 0 | -0.290 | 0.0200 | 0.120 | 0.250 | 1.9 | L26 | C4 |
| 270 | Hypurity C8 | Thermo/Hypersil | B | 0.830 | 0.0100 | -0.200 | 0.0300 | 0.150 | 0.160 | 3.5 | L7 | C8 |
| 271 | Hypurity Cyano | Thermo/Hypersil | CN | 0.450 | -0.0400 | -0.490 | 0.0200 | -0.0100 | 0.830 | 0.7 | L10 | CN |
| 272 | Hypersil Prism C18 RP | Thermo/Hypersil | EP | 0.640 | 0.0800 | -0.450 | 0.300 | -2.81 | -0.710 | 4.8 | | EP |
| 273 | Hypersil Prism C18 RPN | Thermo/Hypersil | EP | 0.670 | 0 | -0.0600 | 0.230 | -0.540 | 0.620 | 3.4 | | EP |
| 274 | Hypurity Advance | Thermo/Hypersil | EP | 0.410 | -0.0500 | -0.0900 | 0.240 | -1.33 | 0.780 | 1.6 | L60 | EP |
| 275 | Fluophase PFP | Thermo/Hypersil | F | 0.670 | -0.120 | -0.310 | 0.0600 | 0.810 | 1.37 | 4.5 | L43 | F |
| 276 | Fluophase RP | Thermo/Hypersil | F | 0.690 | 0.0200 | 0.100 | 0.0300 | 1.03 | 1.41 | 3.4 | L43 | F |
| 277 | BetaBasic Phenyl | Thermo/Hypersil | phenyl | 0.580 | -0.150 | -0.410 | 0.0400 | 0.100 | 0.750 | 1.7 | L11 | Phenyl |
| 278 | Betasil Phenyl-Hexyl | Thermo/Hypersil | phenyl | 0.700 | -0.0500 | -0.290 | 0.0200 | 0.0500 | 0.350 | 4.3 | L11 | Phenyl |
| 279 | OmniSpher 5 C18 | Agilent Technologies/Varian | B | 1.05 | 0.0500 | -0.0300 | -0.0200 | 0.120 | 0.0500 | 10.9 | L1 | C18 |
| 280 | Polaris C18-A | Agilent Technologies/Varian | EP | 0.920 | 0 | -0.220 | 0.0600 | 0.140 | 0.160 | 5.2 | L1 | EP |
| 281 | Polaris C8-A | Agilent Technologies/Varian | EP | 0.600 | 0 | -0.600 | 0.100 | -0.0700 | 0.200 | 2.2 | L7 | EP |
| 282 | Pursuit C18 | Agilent Technologies/Varian | B | 1.00 | 0 | -0.160 | 0.0100 | 0.240 | 0.220 | 6.2 | L1 | C18 |
| 283 | MicroBondapak C18 | Waters | A | 0.790 | -0.0700 | -0.0300 | 0.0100 | 0.280 | 0.850 | 4.6 | L1 | C18 |
| 284 | Nova-Pak C18 | Waters | A | 1.04 | 0 | 0.0900 | -0.0200 | 0.540 | 0.560 | 6.5 | L1 | C18 |
| 285 | Nova-Pak C8 | Waters | A | 0.890 | -0.0200 | -0.0900 | 0 | 0.610 | 0.620 | 3.9 | L7 | C8 |
| 286 | Resolve C18 | Waters | A | 0.960 | -0.120 | 0.330 | -0.0400 | 1.92 | 2.14 | 7.9 | L1 | C18 |
| 287 | Spherisorb C8 | Waters | A | 0.760 | -0.0900 | -0.0300 | 0.0500 | 0.730 | 1.14 | 4.9 | L7 | C8 |
| 288 | Spherisorb ODS-1 | Waters | A | 0.680 | -0.180 | 0.320 | 0.0100 | 0.840 | 1.29 | 4.6 | L1 | C18 |
| 289 | Spherisorb ODS-2 | Waters | A | 0.960 | -0.0700 | 0.0700 | 0.0300 | 0.900 | 1.26 | 8.3 | L1 | C18 |
| 290 | Spherisorb S5 ODSB | Waters | B | 0.970 | 0.0200 | 0.240 | 0.380 | -0.640 | 1.68 | 6.9 | L1 | C18 |
| 291 | Atlantis dC18 | Waters | B | 0.910 | -0.0300 | -0.190 | 0 | 0.0300 | 0.0800 | 8.1 | L1 | C18 |
| 292 | DeltaPak C18 100A | Waters | B | 1.02 | 0.0100 | -0.0100 | -0.0100 | -0.0500 | 0.0200 | 9 | L1 | C18 |
| 293 | DeltaPak C18 300A | Waters | B | 0.950 | -0.0100 | -0.100 | 0.0100 | 0.230 | 0.280 | 3 | L1 | C18 |
| 294 | J'Sphere H80 | YMC | B | 1.13 | 0.0500 | -0.0200 | -0.0600 | -0.240 | -0.160 | 13.3 | L1 | C18 |
| 295 | J'Sphere L80 | YMC | B | 0.760 | -0.0300 | -0.210 | 0 | -0.400 | 0.340 | 5.8 | L1 | C18 |
| 296 | J'Sphere M80 | YMC | B | 0.920 | -0.0200 | -0.120 | 0 | -0.290 | 0.130 | 9.1 | L1 | C18 |
| 297 | Sunfire C8 | Waters | B | 0.850 | 0.0300 | -0.120 | 0 | -0.270 | 0 | 5.8 | L7 | C8 |
| 298 | Sunfire C18 | Waters | B | 1.03 | 0.0300 | 0.0400 | -0.0100 | -0.180 | -0.0900 | 9.9 | L1 | C18 |
| 299 | Symmetry 300 C18 | Waters | B | 0.980 | 0.0300 | -0.0500 | 0 | 0.220 | 0.200 | 3.5 | L1 | C18 |
| 300 | Symmetry 300 C4 | Waters | B | 0.650 | -0.0100 | -0.420 | 0.0100 | 0.100 | 0.180 | 1.4 | L26 | C4 |
| 301 | Symmetry C18 | Waters | B | 1.05 | 0.0600 | 0.0100 | -0.0200 | -0.300 | 0.120 | 9.8 | L1 | C18 |
| 302 | Symmetry C8 | Waters | B | 0.890 | 0.0400 | -0.200 | 0.0200 | -0.500 | 0.280 | 7 | L7 | C8 |
| 303 | XTerra MS C18 | Waters | B | 0.980 | 0.0100 | -0.140 | -0.0100 | 0.130 | 0.0500 | 6.3 | L1 | C18 |
| 304 | XTerra MS C8 | Waters | B | 0.800 | 0 | -0.290 | 0 | 0.0500 | 0 | 3.7 | L7 | C8 |
| 305 | YMC Basic | YMC | B | 0.820 | 0 | -0.230 | 0.0200 | 0.0700 | 0.0900 | 3.3 | L7 | C8 |
| 306 | YMC Hydrosphere C18 | YMC | B | 0.930 | -0.0200 | -0.120 | 0 | -0.130 | 0.150 | 6.8 | L1 | C18 |
| 307 | YMC-Pack ODS-AQ | YMC | B | 0.960 | -0.0300 | -0.130 | 0 | -0.0600 | 0.100 | 8.6 | L1 | C18 |
| 308 | YMC-Pack Pro C18 RS | YMC | B | 1.11 | 0.0500 | -0.0600 | -0.0500 | -0.170 | -0.220 | 12.7 | L1 | C18 |
| 309 | YMC-Pack Pro C18 | YMC | B | 1.01 | 0.0100 | -0.120 | 0 | -0.150 | 0 | 8.7 | L1 | C18 |
| 310 | YMC-Pack Pro C8 | YMC | B | 0.890 | 0.0100 | -0.210 | 0 | -0.320 | 0.0100 | 6.5 | L7 | C8 |
| 311 | Nova-Pak CN HP 60A | Waters | CN | 0.360 | -0.160 | 0.100 | 0 | 0.690 | 1.17 | 0.4 | L10 | CN |
| 312 | SymmetryShield C18 | Waters | EP | 0.850 | 0.0200 | -0.410 | 0.0900 | -0.720 | 0.130 | 7.3 | | EP |
| 313 | SymmetryShield C8 | Waters | EP | 0.730 | 0 | -0.550 | 0.100 | -0.620 | 0.130 | 5.7 | | EP |
| 314 | XTerra C18 RP | Waters | EP | 0.750 | -0.0400 | -0.480 | 0.0900 | -0.170 | -0.170 | 4.3 | | EP |
| 315 | XTerra C8 RP | Waters | EP | 0.650 | -0.0400 | -0.600 | 0.0900 | -0.180 | -0.190 | 3.1 | | EP |
| 316 | XTerra Phenyl | Waters | phenyl | 0.680 | -0.0700 | -0.360 | 0 | 0.110 | 0.0200 | 2.6 | L11 | Phenyl |
| 317 | MicroBondapak Phenyl | Waters | phenyl | 0.580 | -0.150 | -0.240 | 0.0200 | 0.350 | 0.970 | 2.1 | L11 | Phenyl |
| 318 | Nova-Pak Phenyl | Waters | phenyl | 0.700 | -0.150 | -0.300 | 0.0100 | 0.760 | 0.810 | 2.5 | L11 | Phenyl |
| 319 | ZirChrom-EZ | ZirChrom | other | 1.04 | 0.110 | -0.990 | 0 | 2.08 | 2.08 | 1.1 | | Other |
| 320 | ZirChrom-PBD | ZirChrom | other | 1.28 | 0.150 | -0.380 | -0.0700 | 2.18 | 2.18 | 1 | L49 | Other |
| 321 | ZirChrom-PS | ZirChrom | other | 0.580 | -0.230 | -0.470 | 0.0600 | 1.75 | 1.75 | 0.3 | | Other |
| 322 | Cadenza 5CL-C18 | Imtakt | B | 1.01 | 0 | 0.0900 | -0.0400 | 0.140 | 0.300 | 9.2 | L1 | C18 |
| 323 | Cogent hQ C18 | MicroSolv | B | 0.900 | -0.0600 | 0.370 | 0 | 0.190 | 2.18 | 8.1 | L1 | C18 |
| 324 | Cogent Bidentate C18 | MicroSolv | A | 0.950 | 0.0500 | -0.130 | 0 | 0.780 | 2.26 | 5.6 | L1 | C18 |
| 325 | Cogent HPS C18 | MicroSolv | B | 1.02 | -0.0100 | -0.0700 | -0.0100 | 0.100 | 0.0800 | 10.2 | L1 | C18 |
| 326 | Cogent UDC Cholesterol | MicroSolv | other | 0.620 | 0.220 | 0.520 | 0.0600 | 0.740 | 1.21 | 3.4 | | Other |
| 327 | Atlantis T3 | Waters | B | 0.940 | -0.0300 | -0.180 | 0 | 0.0200 | 0.710 | 8.4 | L1 | C18 |
| 328 | Halo C18 | Advanced Materials Technology | B | 1.10 | 0.0400 | 0 | -0.0500 | 0.0500 | 0.0400 | 6.1 | L1 | C18 |
| 329 | Halo C8 | Advanced Materials Technology | B | 0.910 | 0.0200 | -0.130 | 0 | -0.0100 | 0.180 | 4.3 | L7 | C8 |
| 330 | Acquity UPLC BEH C8 | Waters | B | 0.850 | 0 | 0.0900 | 0.0500 | 0.220 | 0.770 | 2.7 | L7 | C8 |
| 331 | Acquity UPLC BEH Phenyl | Waters | phenyl | 0.760 | -0.0700 | -0.0500 | 0.0600 | 0.290 | 0.580 | 2 | L11 | Phenyl |
| 332 | Acquity UPLC BEH Shield RP-18 | Waters | EP | 0.900 | 0.0100 | -0.0300 | 0.130 | -0.0500 | 0.410 | 3.5 | | EP |
| 333 | Aquasil C18 | Thermo/Hypersil | EP | 0.800 | 0.110 | 0.260 | 0.0100 | 0.230 | 1.19 | 7.4 | | EP |
| 334 | Ascentis C18 | Supelco | B | 1.07 | 0.0500 | 0.0300 | -0.0400 | -0.0800 | -0.0800 | 10.5 | L1 | C18 |
| 335 | Ascentis C8 | Supelco | B | 0.890 | 0.0200 | -0.180 | 0 | -0.120 | -0.0300 | 8.4 | L7 | C8 |
| 336 | Ascentis Express C18 | Supelco | B | 1.13 | 0.0500 | 0.0200 | -0.0500 | 0.0600 | 0.100 | 6.5 | L1 | C18 |
| 337 | Ascentis Express C8 | Supelco | B | 0.910 | 0.0100 | -0.110 | 0 | 0 | 0.170 | 4.6 | L7 | C8 |
| 338 | Ascentis RP-Amide | Supelco | EP | 0.840 | 0.0700 | -0.490 | 0.180 | -0.780 | 0.0800 | 8.8 | L60 | EP |
| 339 | Betasil C18 | Thermo/Hypersil | B | 1.05 | 0.0400 | -0.100 | -0.0300 | -0.0300 | -0.0400 | 11.1 | L1 | C18 |
| 340 | Cogent Bidentate C8 | MicroSolv | B | 0.680 | -0.110 | 0.360 | 0 | 0.190 | 1.35 | 3.7 | L7 | C8 |
| 341 | BioBasic CN | Thermo/Hypersil | CN | 0.390 | -0.0300 | -0.820 | 0 | -0.0700 | 0.530 | 0.4 | L10 | CN |
| 342 | BioBasic Phenyl | Thermo/Hypersil | phenyl | 0.490 | -0.230 | -0.670 | 0.210 | 0.0100 | 0.390 | 0.8 | L11 | Phenyl |
| 343 | BioBasic 4 | Thermo/Hypersil | B | 0.690 | 0 | -0.190 | 0.0300 | 0.180 | 0.390 | 1.2 | L26 | C4 |
| 344 | GraceSmart RP 18 | Grace/Alltech | B | 0.830 | -0.0300 | 0.0700 | 0 | 0.0700 | 0.740 | 4 | L1 | C18 |
| 345 | Hypersil GOLD aQ | Thermo/Hypersil | A | 0.910 | -0.0100 | -0.0600 | -0.0100 | 0.370 | 0.630 | 4.1 | L1 | C18 |
| 346 | Hypersil GOLD C8 | Thermo/Hypersil | B | 0.820 | 0.0100 | -0.150 | 0.0300 | 0.0900 | 0.210 | 2.7 | L7 | C8 |
| 347 | Hypersil GOLD PFP | Thermo/Hypersil | F | 0.620 | -0.0800 | -0.110 | -0.0200 | 0.370 | 0.990 | 1.9 | L43 | F |
| 348 | Sepax Bio-C18 | Sepax Technologies | B | 0.910 | -0.0200 | -0.130 | 0.0100 | 0.210 | 0.220 | 2.6 | L1 | C18 |
| 349 | SepaxBio-C4 | Sepax Technologies | B | 0.660 | -0.0100 | -0.290 | 0.0200 | 0.100 | 0.220 | 1.4 | L26 | C4 |
| 350 | SepaxBio-C8 | Sepax Technologies | B | 0.770 | -0.0200 | -0.270 | 0.0200 | 0.160 | 0.210 | 1.6 | L7 | C8 |
| 351 | SepaxGP-C18 | Sepax Technologies | B | 1.01 | 0.0100 | -0.110 | -0.0100 | 0.100 | 0.0900 | 9 | L1 | C18 |
| 352 | SepaxGP-C4 | Sepax Technologies | B | 0.690 | -0.0100 | -0.260 | 0 | -0.0200 | 0.200 | 3.9 | L26 | C4 |
| 353 | SepaxGP-Phenyl | Sepax Technologies | phenyl | 0.570 | -0.110 | -0.270 | 0.0200 | 0.0500 | 0.560 | 2.6 | L11 | Phenyl |
| 354 | SepaxHP-C18 | Sepax Technologies | B | 0.950 | -0.0200 | -0.100 | 0 | 0.0700 | 0.220 | 8.5 | L1 | C18 |
| 355 | SepaxHP-Cyano | Sepax Technologies | CN | 0.420 | -0.0500 | -0.470 | 0 | 0 | 0.750 | 1.3 | L10 | CN |
| 356 | TSKgel CN-80Ts | Tosoh Bioscience | CN | 0.370 | -0.0200 | -0.610 | 0.0100 | -0.360 | 0.420 | 0.9 | L10 | CN |
| 357 | TSKgel Octyl-80Ts | Tosoh Bioscience | B | 0.810 | 0 | -0.250 | 0.0100 | 0.0800 | 0.450 | 4.4 | L7 | C8 |
| 358 | TSKgel ODS-100S | Tosoh Bioscience | B | 1.03 | 0.0600 | -0.0900 | -0.0300 | 0 | -0.0300 | 8.1 | L1 | C18 |
| 359 | TSKgel ODS-100V | Tosoh Bioscience | B | 0.900 | -0.0400 | -0.220 | 0 | -0.0600 | -0.0200 | 9 | L1 | C18 |
| 360 | TSKgel ODS-100Z | Tosoh Bioscience | B | 1.03 | 0.0100 | -0.130 | -0.0300 | -0.0600 | -0.160 | 11.6 | L1 | C18 |
| 361 | TSK-gel ODS-140HTP | Tosoh Bioscience | B | 1.00 | 0.0500 | -0.250 | -0.0300 | 0.130 | 0.140 | 2.8 | L1 | C18 |
| 362 | TSKgel ODS-80Ts | Tosoh Bioscience | B | 0.970 | -0.0100 | -0.130 | 0 | 0.0100 | 0.290 | 8.1 | L1 | C18 |
| 363 | TSKgel ODS-80Ts QA | Tosoh Bioscience | B | 0.940 | -0.0300 | -0.110 | 0 | 0 | 0.360 | 7.8 | L1 | C18 |
| 364 | TSKgel Super-Octyl | Tosoh Bioscience | B | 0.820 | 0.0300 | -0.150 | 0.0100 | 0.120 | 0.230 | 2.2 | L7 | C8 |
| 365 | TSKgel Super-ODS | Tosoh Bioscience | B | 0.990 | 0.0300 | -0.0400 | -0.0100 | 0.150 | 0.230 | 3.8 | L1 | C18 |
| 366 | TSKgel Super-Phenyl | Tosoh Bioscience | phenyl | 0.580 | -0.100 | -0.140 | 0.0100 | 0.0800 | 0.670 | 1 | L11 | Phenyl |
| 367 | VisionHT C18 | Grace/Alltech | B | 0.780 | -0.0700 | -0.0900 | 0 | 0.400 | 0.690 | 4.6 | L1 | C18 |
| 368 | VisionHT C18-P | Grace/Alltech | B | 0.630 | -0.160 | 0.280 | 0.0300 | 0.690 | 1.61 | 2.7 | L1 | C18 |
| 369 | Zorbax Bonus RP | Agilent Technologies | EP | 0.650 | 0.100 | -1.04 | 0.370 | -2.97 | -1.10 | 4.5 | L60 | EP |
| 372 | ACE 5 C18-HL | ACT | B | 1.04 | 0.0500 | -0.0800 | -0.0300 | -0.0300 | -0.110 | 10 | L1 | C18 |
| 373 | Nucleodur Isis | Macherey Nagel | B | 1.02 | 0.0500 | -0.0700 | -0.0200 | -0.0100 | 0.150 | 8.8 | L1 | C18 |
| 374 | Nucleodur Pyramid | Macherey Nagel | B | 0.950 | 0 | -0.130 | -0.0100 | -0.280 | 0.210 | 8 | L1 | C18 |
| 375 | Nucleodur Sphinx RP | Macherey Nagel | phenyl | 0.800 | -0.0700 | -0.270 | 0 | 0.0200 | 0.720 | 5.6 | L1 | Phenyl |
| 376 | Zorbax Eclipse Plus C18 | Agilent Technologies | B | 1.03 | 0 | -0.0700 | -0.0200 | 0 | 0.0200 | 7.8 | L1 | C18 |
| 377 | Zorbax Eclipse Plus C8 | Agilent Technologies | B | 0.880 | 0.0100 | -0.170 | 0 | -0.0400 | 0.0500 | 5.2 | L1 | C18 |
| 378 | Epic C18 | ES Industries | B | 0.950 | -0.0200 | -0.200 | 0 | -0.130 | -0.0400 | 10.7 | L1 | C18 |
| 379 | Epic C8 | ES Industries | B | 0.890 | 0.0200 | -0.190 | 0 | -0.100 | 0.0300 | 8.6 | L7 | C8 |
| 380 | Epic C4 | ES Industries | B | 0.770 | 0.0100 | -0.310 | 0 | -0.200 | 0.0600 | 5.9 | L26 | C4 |
| 381 | Epic Phenyl Hexyl | ES Industries | phenyl | 0.670 | -0.0800 | -0.370 | 0 | -0.140 | 0.300 | 4.5 | L11 | phenyl |
| 382 | Gemini-NX C18 | Phenomenex | B | 0.960 | 0.0100 | -0.200 | -0.0100 | -0.180 | -0.130 | 7.1 | L1 | C18 |
| 383 | Luna PFP(2) | Phenomenex | F | 0.750 | -0.0700 | -0.380 | -0.0500 | 0.0800 | 0.540 | 4.9 | L43 | F |
| 384 | Alltima HP CN | Grace/Alltech | CN | 0.460 | -0.0100 | -0.550 | 0 | -0.180 | 0.440 | 0.9 | L10 | CN |
| 385 | SepaxBR-C18 | Sepax Technologies | B | 1.01 | 0.0300 | -0.0700 | -0.0100 | -0.0100 | 0.0600 | 8.2 | L1 | C18 |
| 386 | SepaxGP-C8 | Sepax Technologies | B | 0.840 | 0 | -0.130 | 0.0100 | -0.0700 | 0.260 | 5.6 | L7 | C8 |
| 387 | Vision C18 B | Grace/Alltech | A | 0.680 | -0.110 | 0.350 | 0.0300 | 0.390 | 1.41 | 2.9 | L1 | C18 |
| 388 | Vision C18 HL | Grace/Alltech | B | 0.990 | 0.0500 | 0.0500 | -0.0100 | 0.130 | 0.140 | 6.3 | L1 | C18 |
| 389 | Capcell Pak C18 IF | Shiseido | B | 0.950 | 0.0200 | -0.200 | 0 | -0.200 | -0.0100 | 3.8 | L1 | C18 |
| 390 | Capcell Pak C18 MG III | Shiseido | B | 0.950 | 0 | -0.110 | -0.0100 | -0.110 | 0.0400 | 9.3 | L1 | C18 |
| 391 | Grom-Sil 120 ODS-4 HE | Grace/Grom | B | 0.970 | -0.0300 | -0.0800 | 0.0100 | -0.0300 | 0.260 | 6.8 | L1 | C18 |
| 392 | ZodiacSil 60-5-C18H | Zodiac Life Sciences | B | 1.15 | 0.0400 | 0.0600 | -0.0700 | 0.100 | 0.260 | 12.2 | L1 | C18 |
| 393 | ZodiacSil 120-5-C18 ace EPS | Zodiac Life Sciences | EP | 0.770 | 0.0400 | -0.590 | 0.220 | -0.300 | 0.0400 | 8.3 | | EP |
| 394 | ZodiacSil 120-5 C18 AQ | Zodiac Life Sciences | B | 0.970 | 0 | -0.0800 | 0 | 0.130 | 0.220 | 8.1 | L1 | C18 |
| 395 | ZodiacSil 120-5-C18 AQ Plus | Zodiac Life Sciences | EP | 0.940 | -0.0100 | 0.210 | 0.0400 | -0.130 | 0.600 | 9.1 | | EP |
| 396 | ZodiacSil 120-5-C18H | Zodiac Life Sciences | B | 1.00 | 0 | -0.100 | 0 | 0.120 | 0.150 | 9.7 | L1 | C18 |
| 397 | ZodiacSil 120-5-C18SH | Zodiac Life Sciences | B | 1.03 | 0.0100 | -0.100 | -0.0200 | 0.110 | 0.400 | 8.7 | L1 | C18 |
| 398 | ZodiacSil 200-5-C18 ace EPS | Zodiac Life Sciences | EP | 0.760 | 0.0200 | -0.560 | 0.210 | 0.0200 | 0.140 | 4.7 | | EP |
| 399 | ZodiacSil 200-5-C18H | Zodiac Life Sciences | B | 0.950 | 0 | -0.120 | 0.0100 | 0.160 | 0.210 | 4.8 | L1 | C18 |
| 400 | ZodiacSil 200-5-C18AQ | Zodiac Life Sciences | B | 0.970 | -0.0100 | -0.0500 | 0 | 0.120 | 0.0200 | 6.3 | L1 | C18 |
| 402 | ZodiacSil 300-5-C18ace EPS | Zodiac Life Sciences | EP | 0.760 | 0.0200 | -0.570 | 0.210 | -0.0500 | 0.130 | 2.9 | | EP |
| 403 | ZodiacSil 300-5-C18H | Zodiac Life Sciences | B | 0.950 | -0.0100 | -0.0900 | 0.0100 | 0.240 | 0.240 | 3.2 | L1 | C18 |
| 404 | XBridge C18 | Waters | B | 1.00 | 0.0200 | -0.0900 | 0 | 0.170 | 0.130 | 4.6 | L1 | C18 |
| 405 | XBridge Phenyl | Waters | phenyl | 0.730 | -0.0700 | -0.350 | 0.0300 | 0.190 | 0.200 | 2.4 | L11 | Phenyl |
| 406 | XBridge Shield RP18 | Waters | EP | 0.830 | -0.0200 | -0.370 | 0.0900 | -0.120 | -0.0500 | 3.7 | | EP |
| 407 | ACE 5 C18-AR | ACT | phenyl | 0.880 | -0.0500 | -0.200 | -0.0100 | 0.0700 | 0.150 | 5.7 | L1 | Phenyl |
| 408 | Allure Aqueous C18 | Restek | B | 0.960 | -0.100 | 0.390 | -0.0400 | 0 | 1.38 | 17 | L1 | C18 |
| 409 | Allure Basix | Restek | CN | 0.430 | -0.0700 | -0.420 | 0 | 0.0100 | 0.860 | 2.4 | Other | CN |
| 410 | Allure Biphenyl | Restek | phenyl | 0.710 | -0.190 | -0.290 | 0.0200 | -0.0100 | 0.690 | 7.2 | | Phenyl |
| 411 | Allure Organic Acids | Restek | B | 0.910 | -0.120 | 0.530 | -0.0200 | 0.190 | 1.50 | 14.5 | L1 | C18 |
| 412 | Ascentis Express RP-Amide | Supelco | EP | 0.840 | 0.0600 | -0.410 | 0.190 | -0.470 | 0.260 | 5.1 | L60 | EP |
| 413 | Ascentis Phenyl | Supelco | phenyl | 0.720 | -0.100 | -0.280 | 0 | 0 | 0.570 | 4.8 | L11 | Phenyl |
| 414 | Clipeus C18 | Higgins Analytical | B | 1.00 | 0 | -0.0400 | -0.0100 | 0.0700 | 0.340 | 9.5 | L1 | C18 |
| 415 | Clipeus C8 | Higgins Analytical | B | 0.820 | -0.0100 | -0.180 | 0.0200 | 0.0900 | 0.240 | 4.9 | L7 | C8 |
| 416 | Clipeus Cyano | Higgins Analytical | CN | 0.420 | -0.0600 | -0.420 | 0.0100 | 0.0500 | 0.780 | 1.2 | L10 | CN |
| 417 | Clipeus Phenyl | Higgins Analytical | phenyl | 0.580 | -0.110 | -0.300 | 0.0300 | 0.0700 | 0.480 | 2.5 | L11 | Phenyl |
| 418 | Discovery HS F5 | Supelco | F | 0.670 | 0.0800 | -0.280 | 0 | 0.910 | 1.42 | 4.1 | L43 | F |
| 419 | Gemini C6-Phenyl 110A | Phenomenex | phenyl | 0.800 | 0.0300 | -0.340 | 0 | -0.400 | -0.260 | 4.8 | L11 | Phenyl |
| 420 | Haisil 300 C18 | Higgins Analytical | A | 0.940 | 0 | -0.0300 | 0 | 0.420 | 0.680 | 2.2 | L1 | C18 |
| 421 | Haisil HL C18 | Higgins Analytical | B | 1.04 | -0.0300 | -0.0700 | -0.0200 | 0.0400 | -0.0500 | 10.4 | L1 | C18 |
| 422 | Halo Phenyl-Hexyl | Advanced Materials Technology | B | 0.780 | -0.0900 | -0.230 | 0 | 0.100 | 0.450 | 3.5 | L11 | Phenyl |
| 423 | Halo RP-Amide | Advanced Materials Technology | B | 0.850 | 0.0800 | -0.380 | 0.190 | -0.410 | 0.310 | 4.6 | L60 | EP |
| 424 | Heavy C18 | Higgins Analytical | B | 1.04 | 0.0300 | -0.130 | -0.0300 | -0.0800 | -0.120 | 11.5 | L1 | C18 |
| 425 | HyperClone BDS C18 130A | Phenomenex | B | 0.980 | 0.0300 | 0.0100 | -0.0100 | 0.190 | 0.420 | 5.3 | L1 | C18 |
| 426 | HyperClone BDS C8 130A | Phenomenex | B | 0.840 | 0 | -0.140 | 0.0100 | 0.230 | 0.260 | 3.9 | L7 | C8 |
| 427 | HyperClone CN (CPS) | Phenomenex | CN | 0.400 | -0.0800 | -0.550 | 0 | 0.920 | 1.04 | 0.8 | L10 | CN |
| 428 | HyperClone MOS C8 120A | Phenomenex | EP | 0.840 | -0.0500 | 0.0400 | 0.130 | 1.14 | 1.12 | 3.7 | L60 | EP |
| 429 | HyperClone ODS C18 120A | Phenomenex | A | 1.03 | -0.0200 | 0.0600 | 0.0900 | 1.03 | 0.960 | 6.1 | L1 | C18 |
| 430 | HyperClone PAH | Phenomenex | other | 0.980 | 0 | 0.180 | -0.0200 | 1.16 | 1.11 | 4.9 | | Other |
| 431 | Inertsil ODS-4 | GL Sciences | B | 0.910 | -0.0200 | -0.220 | -0.0300 | -0.0200 | -0.140 | 9.1 | L1 | C18 |
| 432 | Inertsil ODS-SP | GL Sciences | B | 0.850 | -0.0200 | -0.220 | -0.0200 | -0.0400 | -0.0700 | 7.8 | L1 | C18 |
| 433 | Kinetex C18 100A | Phenomenex | B | 0.960 | 0 | -0.130 | -0.0100 | 0 | 0.120 | 4.9 | L1 | C18 |
| 434 | Kinetex PFP 100A | Phenomenex | F | 0.680 | 0.0800 | -0.270 | -0.0300 | 0.940 | 1.53 | 2.4 | L43 | F |
| 435 | Microsorb 100-5 C8 | Agilent Technologies/Varian | A | 0.870 | 0.0600 | 0.0900 | 0.190 | 0.610 | 0.820 | 5.4 | L7 | C8 |
| 436 | Microsorb 100-5 Phenyl | Agilent Technologies/Varian | phenyl | 0.710 | -0.140 | -0.190 | 0.160 | 0.600 | 0.780 | 3.1 | L11 | phenyl |
| 437 | Microsorb 300-5 C4 | Agilent Technologies/Varian | B | 0.660 | -0.0200 | -0.310 | 0.0300 | 0.200 | 0.410 | 1 | L26 | C4 |
| 438 | Microsorb-MV 100 CN | Agilent Technologies/Varian | CN | 0.350 | -0.240 | -0.850 | -0.0200 | 0.140 | 0.780 | 1.3 | L10 | CN |
| 439 | Nucleodur 100-5 C18 | Macherey Nagel | B | 0.970 | -0.0200 | 0 | -0.0300 | 0.140 | 0.590 | 9.7 | L1 | C18 |
| 440 | Nucleodur 100-5 C8 | Macherey Nagel | B | 0.770 | -0.0400 | -0.150 | 0 | 0.0400 | 0.820 | 5.4 | L1 | C18 |
| 441 | Phalanx C18 | Higgins Analytical | B | 0.950 | -0.0300 | -0.200 | 0 | -0.0700 | -0.0100 | 10.4 | L1 | C18 |
| 442 | Pinnacle DB Aqueous C18 | Restek | A | 0.690 | -0.140 | 0.220 | 0.0300 | 0.370 | 1.13 | 3.5 | L1 | C18 |
| 443 | Pinnacle DB Biphenyl | Restek | phenyl | 0.640 | -0.170 | -0.340 | 0.0500 | 0.190 | 0.510 | 2.3 | L11 | Phenyl |
| 444 | Pinnacle DB C18 | Restek | A | 1.01 | 0.0200 | -0.0300 | 0 | 0.360 | 0.280 | 6.3 | L1 | C18 |
| 445 | Pinnacle DB C8 | Restek | A | 0.830 | 0 | -0.190 | 0.0300 | 0.260 | 0.230 | 3.8 | L7 | C8 |
| 446 | Pinnacle DB Cyano | Restek | CN | 0.370 | -0.0700 | -0.380 | 0 | 0.220 | 0.720 | 0.7 | L10 | CN |
| 447 | Pinnacle DB PFP Propyl | Restek | F | 0.640 | -0.0600 | -0.250 | 0.0500 | 0.590 | 1.10 | 2.5 | L43 | F |
| 448 | Pinnacle DB Phenyl | Restek | phenyl | 0.570 | -0.120 | -0.460 | 0.0400 | 0.160 | 0.280 | 1.7 | L11 | Phenyl |
| 449 | Pinnacle II Biphenyl | Restek | phenyl | 0.640 | -0.190 | -0.240 | 0.0500 | 0.460 | 0.730 | 2.9 | L11 | Phenyl |
| 450 | Pinnacle II C18 | Restek | A | 1.03 | 0.0100 | -0.0300 | 0 | 0.440 | 0.340 | 8.4 | L1 | C18 |
| 451 | Pinnacle II C8 | Restek | A | 0.850 | 0 | -0.110 | 0.0300 | 0.390 | 0.430 | 5.3 | L7 | C8 |
| 452 | Pinnacle II Cyano | Restek | CN | 0.370 | -0.0800 | -0.210 | -0.0100 | 0.200 | 0.780 | 1.2 | L10 | CN |
| 453 | Pinnacle II PAH | Restek | A | 0.970 | -0.0200 | 0.350 | -0.0200 | 0.740 | 1.18 | 6.8 | L1 | C18 |
| 454 | Pinnacle II Phenyl | Restek | phenyl | 0.590 | -0.130 | -0.400 | 0.0600 | 0.370 | 0.490 | 2.3 | L11 | Phenyl |
| 455 | Polaris Amide-C18 | Agilent Technologies/Varian | EP | 0.840 | 0.110 | -0.330 | 0.340 | -1.65 | -0.550 | 4.2 | L60 | EP |
| 456 | Proto 300 C18 | Higgins Analytical | B | 0.960 | 0.0100 | -0.130 | 0 | 0.220 | 0.140 | 2.9 | L1 | C18 |
| 457 | Pursuit DP | Agilent Technologies/Varian | phenyl | 0.570 | -0.130 | -0.530 | 0.0400 | 0.150 | 0.260 | 1.7 | | Phenyl |
| 458 | Pursuit PFP | Agilent Technologies/Varian | F | 0.650 | -0.0800 | -0.250 | -0.0200 | 0.0500 | 0.530 | 2.2 | L43 | F |
| 459 | Pursuit UPS C18 | Agilent Technologies/Varian | B | 1.06 | 0.0600 | -0.0500 | 0 | -0.0700 | 0.200 | 4.6 | L1 | C18 |
| 460 | Targa C8 | Higgins Analytical | B | 0.820 | -0.0200 | -0.220 | 0 | -0.0200 | 0.170 | 6 | L7 | C8 |
| 461 | TSKgel ODS-120A | Tosoh Bioscience | B | 0.890 | -0.0300 | 0.280 | 0 | 0.260 | 0.960 | 6.5 | L1 | C18 |
| 462 | TSKgel ODS-120T | Tosoh Bioscience | B | 0.970 | 0.0300 | 0.110 | -0.0100 | 0.190 | 0.220 | 6.5 | L1 | C18 |
| 463 | TSKgel ODS-80T | Tosoh Bioscience | B | 0.960 | -0.0300 | 0.140 | -0.0100 | 0.160 | 0.580 | 8.3 | L1 | C18 |
| 464 | TSKgel OligoDNA RP | Tosoh Bioscience | A | 0.860 | 0.0200 | 0.140 | 0.0100 | 0.310 | 0.650 | 3.3 | L1 | C18 |
| 465 | Ultra Aqueous C18 | Restek | B | 0.800 | -0.120 | 0.370 | 0.0100 | 0.220 | 1.25 | 8.1 | L1 | C18 |
| 466 | Ultra Biphenyl | Restek | phenyl | 0.660 | -0.180 | -0.280 | 0.0400 | 0.200 | 0.720 | 3.9 | L11 | Phenyl |
| 467 | Ultra C1 | Restek | B | 0.610 | -0.0500 | -0.400 | 0.0100 | -0.0300 | 0.0500 | 3.5 | L13 | C1 |
| 468 | Ultra C4 | Restek | B | 0.730 | -0.0100 | -0.270 | 0.0100 | 0.0300 | 0.310 | 5.2 | L26 | C4 |
| 469 | Ultra Cyano | Restek | CN | 0.400 | -0.0400 | -0.800 | -0.0100 | -0.110 | 0.620 | 1.6 | L10 | CN |
| 470 | Ultra IBD | Restek | EP | 0.670 | -0.0300 | -0.0500 | 0.230 | -0.560 | 0.860 | 4.6 | L68 | EP |
| 471 | Ultra II Aqueous C18 | Restek | B | 0.780 | -0.150 | 0.320 | 0.0100 | 0.460 | 1.16 | 7.4 | L1 | C18 |
| 472 | Ultra II Aromax | Restek | phenyl | 0.730 | -0.190 | -0.340 | 0.0200 | 0.470 | 0.640 | 5.3 | L11 | Phenyl |
| 473 | Ultra II C18 | Restek | B | 1.04 | 0.0200 | -0.0300 | -0.0100 | 0.260 | 0.180 | 10.8 | L1 | C18 |
| 474 | Ultra II IBD | Restek | EP | 0.670 | -0.0400 | -0.0200 | 0.220 | -0.250 | 0.860 | 4 | L68 | EP |
| 475 | Ultra II PFP Propyl | Restek | F | 0.670 | -0.0800 | -0.300 | 0 | 0.760 | 1.21 | 4.3 | L43 | F |
| 476 | Ultra PFP | Restek | F | 0.440 | -0.0500 | -0.240 | 0.0100 | -0.220 | 0.150 | 1.6 | L43 | F |
| 477 | Ultra Phenyl | Restek | phenyl | 0.580 | -0.120 | -0.330 | 0.0300 | 0.0400 | 0.430 | 3 | L11 | Phenyl |
| 478 | Ultra Quat | Restek | other | 0.850 | 0.0100 | -0.170 | 0.0100 | 0.0200 | 0.130 | 7.3 | | Other |
| 479 | Viva Biphenyl | Restek | phenyl | 0.600 | -0.180 | -0.300 | 0.0400 | 0.330 | 0.540 | 1.3 | L11 | Phenyl |
| 480 | Viva C18 | Restek | A | 0.980 | 0.0100 | -0.0700 | 0.0100 | 0.350 | 0.300 | 4 | L1 | C18 |
| 481 | Viva C4 | Restek | A | 0.700 | -0.0100 | -0.280 | 0.0300 | 0.220 | 0.310 | 1.7 | L26 | C4 |
| 482 | Viva C8 | Restek | A | 0.830 | 0 | -0.220 | 0.0300 | 0.260 | 0.220 | 2.6 | L7 | C8 |
| 483 | Viva PFP Propyl | Restek | F | 0.620 | -0.0600 | -0.250 | 0.0200 | 0.280 | 0.760 | 1.5 | L43 | F |
| 484 | XBridge C8 | Waters | B | 0.800 | 0.0100 | -0.290 | 0.0100 | 0.120 | 0.0600 | 3.4 | L7 | C8 |
| 485 | ZirChrom-MS | ZirChrom | other | 0.940 | -0.170 | -0.450 | 0.320 | 0.480 | 0.550 | 2 | | Other |
| 486 | Zorbax Eclipse PAH | Agilent Technologies | B | 1.03 | -0.0100 | 0.680 | -0.0500 | 0.0700 | 1.40 | 5.9 | L1 | C18 |
| 488 | Peerless Basic C-18 | Chromatopak | B | 0.980 | -0.0100 | -0.150 | -0.0100 | -0.160 | -0.0900 | 11.7 | L1 | C18 |
| 489 | Peerless C-18 | Chromatopak | B | 0.990 | -0.0200 | 0.0300 | -0.0100 | 0 | 0.450 | 10.2 | L1 | C18 |
| 490 | Pursuit XRs C-18 | Agilent Technologies/Varian | B | 1.04 | 0.0300 | -0.120 | -0.0300 | -0.0100 | -0.100 | 11.7 | L1 | C18 |
| 491 | Pursuit XRs C-8 | Agilent Technologies/Varian | B | 0.880 | 0.0200 | -0.220 | 0 | -0.150 | -0.0600 | 8.2 | L7 | C8 |
| 492 | Pursuit XRs DP | Agilent Technologies/Varian | phenyl | 0.630 | -0.130 | -0.430 | 0.0300 | 0.0400 | 0.390 | 4 | | Phenyl |
| 493 | Biobond C18 | Dikma Technologies | B | 0.960 | -0.0200 | -0.150 | 0 | 0.220 | 0.180 | 3.1 | L1 | C18 |
| 494 | Biobond C4 | Dikma Technologies | B | 0.700 | 0 | -0.310 | 0.0200 | 0.140 | 0.180 | 1.4 | L26 | C4 |
| 495 | Biobond C8 | Dikma Technologies | B | 0.820 | 0 | -0.260 | 0.0200 | 0.170 | 0.150 | 2 | L7 | C8 |
| 496 | Inspire C18 | Dikma Technologies | B | 1.06 | -0.0500 | -0.0700 | -0.0400 | -0.0800 | -0.100 | 11.2 | L1 | C18 |
| 497 | Inspire C8 | Dikma Technologies | B | 0.880 | -0.0200 | -0.210 | 0 | -0.190 | -0.0100 | 8.1 | L7 | C8 |
| 498 | Spursil C18 | Dikma Technologies | A | 0.960 | 0 | -0.180 | -0.0400 | 0.420 | 0.760 | 9.1 | L1 | C18 |
| 499 | Spursil C18-EP | Dikma Technologies | EP | 0.830 | 0.100 | -0.500 | 0.220 | -1.12 | 0.890 | 8.9 | L60 | EP |
| 500 | Fortis C18 | Fortis Technologies | B | 0.960 | -0.0200 | -0.180 | 0 | -0.160 | 0.110 | 11 | L1 | C18 |
| 501 | Fortis C8 | Fortis Technologies | B | 0.870 | 0.0200 | -0.220 | 0 | -0.140 | -0.0400 | 8.2 | L7 | C8 |
| 502 | Fortis Cyano | Fortis Technologies | CN | 0.380 | -0.0500 | -0.390 | 0.0100 | 0.0100 | 0.870 | 1.1 | L10 | CN |
| 503 | Fortis H2O | Fortis Technologies | EP | 1.03 | 0.0300 | 0.140 | -0.0200 | 0 | 0.100 | 10.5 | | EP |
| 504 | Fortis Phenyl | Fortis Technologies | phenyl | 0.610 | -0.150 | -0.400 | 0.0300 | 0.0800 | 0.770 | 4 | L11 | phenyl |
| 505 | Fortis UniverSil C18 | Fortis Technologies | B | 0.920 | -0.0200 | -0.120 | 0.0400 | 0.230 | 0.250 | 5.4 | L1 | C18 |
| 506 | Fortis UniverSil HS C18 | Fortis Technologies | B | 0.990 | -0.0100 | -0.110 | -0.0100 | -0.0600 | 0.0800 | 10.6 | L1 | C18 |
| 507 | Inertsil C8-4 | GL Sciences | B | 0.670 | -0.0300 | -0.380 | -0.0100 | -0.0900 | -0.150 | 4.5 | L7 | C8 |
| 508 | Prosphere C18 300A | Grace/Alltech | A | 0.900 | -0.0100 | 0.170 | 0.0100 | 0.570 | 1.26 | 2.2 | L1 | C18 |
| 509 | Vydac 218MSC18 | Grace/Vydac | B | 0.880 | -0.0100 | 0.290 | 0 | 0.170 | 0.820 | 1.6 | L1 | C18 |
| 510 | Vydac C18 Monomeric | Grace/Vydac | B | 0.970 | 0.0400 | 0.0300 | 0 | 0.130 | 0.270 | 2.2 | L1 | C18 |
| 511 | Cadenza CD-C18 | Imtakt | B | 1.05 | 0.0300 | 0.0800 | -0.0200 | 0.110 | 0.0400 | 9.9 | L1 | C18 |
| 513 | Ultra II Biphenyl | Restek | phenyl | 0.650 | -0.190 | -0.270 | 0.0400 | 0.430 | 0.760 | 3.9 | L11 | Phenyl |
| 514 | Sepax HP-C18(2) | Sepax Technologies | B | 0.950 | -0.0200 | -0.180 | 0 | -0.130 | 0.0500 | 11.3 | L1 | C18 |
| 515 | apHera C18 Polymer | Supelco | B | 0.830 | -0.0100 | -1.10 | 0 | -0.550 | 7.51 | 6.3 | L67 | C18 |
| 516 | Ascentis ES Cyano | Supelco | CN | 0.540 | -0.100 | -0.490 | 0.0100 | 0.130 | -0.440 | 2.9 | L10 | CN |
| 517 | Ascentis Express Peptide ES-C18 | Supelco | B | 0.910 | -0.0400 | 0.260 | 0.0100 | 0.190 | 0.810 | 3.6 | | C18 |
| 518 | Ascentis Express Phenyl-Hexyl | Supelco | phenyl | 0.790 | -0.0800 | -0.260 | -0.0100 | 0.0900 | 0.480 | 3.5 | L11 | Phenyl |
| 519 | HSS C18 | Waters | B | 1.02 | 0.0300 | -0.130 | -0.0200 | 0.0500 | 0 | 8.6 | L1 | C18 |
| 520 | HSS C18 SB | Waters | B | 0.730 | -0.120 | 0.400 | 0.0200 | 0.400 | 1.41 | 4 | L1 | C18 |
| 521 | HSS T3 | Waters | B | 0.940 | -0.0200 | -0.170 | 0 | 0.0300 | 0.180 | 7.9 | L1 | C18 |
| 522 | YMC-Triart C18 | YMC | B | 0.920 | -0.0200 | -0.190 | -0.0300 | -0.0200 | -0.130 | 9.4 | L1 | C18 |
| 523 | Endeavorsil C18 | Dikma Technologies | B | 1.02 | 0.0400 | -0.0900 | -0.0200 | -0.0700 | 0 | 4.05 | L1 | C18 |
| 524 | Leapsil C18 | Dikma Technologies | B | 1.05 | 0.0400 | -0.0700 | -0.0300 | -0.0200 | -0.0500 | 10.51 | L1 | C18 |
| 525 | LaChrom C18 | Hitachi High-Tech | B | 0.990 | 0.0100 | -0.150 | 0 | -0.270 | -0.120 | 8.2 | L1 | C18 |
| 526 | LaChrom C18-AQ | Hitachi High-Tech | B | 0.900 | -0.0200 | -0.130 | 0.0100 | -0.320 | 0.190 | 6.8 | L1 | C18 |
| 527 | LaChrom C18-NE | Hitachi High-Tech | B | 0.960 | -0.0200 | 0.360 | 0 | 0.130 | 0.770 | 7.6 | L1 | C18 |
| 528 | LaChrom C8 | Hitachi High-Tech | B | 0.850 | 0.0200 | -0.190 | 0.0100 | -0.410 | -0.0200 | 5.4 | L7 | C8 |
| 529 | LaChrom CN | Hitachi High-Tech | CN | 0.420 | -0.0600 | -0.370 | 0 | -0.0200 | 0.790 | 1.13 | L10 | CN |
| 530 | LaChrom Ph | Hitachi High-Tech | phenyl | 0.590 | -0.100 | -0.320 | 0.0200 | 0 | 0.450 | 2.51 | L11 | Phenyl |
| 531 | Kinetex C8 | Phenomenex | B | 0.860 | 0.0100 | -0.200 | 0 | -0.0800 | 0 | 3.5 | L7 | C8 |
| 532 | Kinetex XB-C18 | Phenomenex | B | 0.970 | -0.0100 | -0.0800 | 0.0200 | -0.0400 | 0.300 | 4.9 | L1 | C18 |
| 533 | HALO Peptide ES-C18 | Advanced Materials Technology | B | 0.890 | -0.0590 | 0.250 | 0.0240 | 0.177 | 0.819 | 3 | L1 | C18 |
| 534 | Hitachi LaChrom C18-PM | Hitachi High-Tech | B | 1.13 | 0.0690 | -0.0190 | -0.0680 | -0.267 | -0.144 | 12.4 | L1 | C18 |
| 535 | Ace 5 C18-PFP | ACT | B | 0.899 | -0.0210 | -0.246 | -0.0800 | -0.00100 | -0.995 | 5.9 | L1 | C18 |
| 536 | HALO PFP | Advanced Materials Technology | B | 0.702 | -0.117 | -0.0730 | -0.0620 | 1.17 | 0.972 | 2.3 | L43 | F |
| 537 | Ultra PFP Propyl | Restek | F | 0.622 | -0.102 | -0.314 | -0.0350 | 0.456 | 1.05 | 4.5 | L43 | F |
| 538 | Ultra Aromax | Restek | phenyl | 0.741 | -0.179 | -0.375 | 0.0210 | 0.195 | 0.375 | 5.6 | L11 | Phenyl |
| 539 | Shim-pack XR-C8 | Shimadzu | B | 0.862 | 0.0100 | -0.160 | 0.0170 | -0.0440 | 0.217 | 3.689 | L7 | C8 |
| 540 | Shim-pack XR-ODS | Shimadzu | B | 1.01 | 0.0320 | -0.106 | -0.0180 | -0.0610 | 0.170 | 5.741 | L1 | C18 |
| 541 | Shim-pack XR-Phenyl | Shimadzu | phenyl | 0.705 | -0.0800 | -0.264 | 0.0100 | -0.0210 | 0.486 | 2.656 | L11 | Phenyl |
| 542 | XSelect CSH C18 | Waters | B | 0.954 | -0.00200 | -0.179 | 0.118 | 0.0820 | 0.171 | 5.62 | L1 | C18 |
| 543 | XSelect CSH Fluoro-Phenyl | Waters | F | 0.498 | -0.138 | -0.0520 | 0.0550 | -0.321 | 0.793 | 1.413 | L43 | F |
| 544 | XSelect CSH Phenyl-Hexyl | Waters | phenyl | 0.708 | -0.0590 | -0.435 | 0.129 | -0.0680 | 0.223 | 2.865 | L11 | Phenyl |
| 545 | InertSustain C18 | GL Sciences | B | 1.01 | 0.0550 | -0.152 | -0.0870 | -0.0810 | -0.195 | 11.399 | L1 | C18 |
| 546 | Venusil ASB C18 | Bonna-Agela Technologies, Inc. | B | 0.824 | -0.0660 | 0.166 | 0.0500 | 0.0470 | 0.644 | 3.883 | L1 | C18 |
| 547 | Venusil ASB C8 | Bonna-Agela Technologies, Inc. | B | 0.677 | -0.0780 | -0.00100 | 0.0440 | 0.119 | 0.569 | 2.424 | L7 | C8 |
| 548 | Durashell C18 | Bonna-Agela Technologies, Inc. | B | 1.04 | 0.0410 | -0.0660 | -0.0380 | -0.191 | -0.174 | 10.556 | L1 | C18 |
| 549 | Innoval C18 | Bonna-Agela Technologies, Inc. | B | 1.05 | 0.0490 | -0.0240 | -0.0340 | -0.0660 | 0.0270 | 6.731 | L1 | C18 |
| 550 | Unisol C18 | Bonna-Agela Technologies, Inc. | B | 0.950 | -0.0170 | -0.108 | -0.00900 | -0.108 | 0.0920 | 10.176 | L1 | C18 |
| 551 | Venusil XBP C18(2) | Bonna-Agela Technologies, Inc. | B | 1.01 | 0.00700 | -0.0810 | -0.0220 | -0.116 | 0.0720 | 11.451 | L1 | C18 |
| 552 | Venusil XBP C18(L) | Bonna-Agela Technologies, Inc. | B | 0.945 | 0.0250 | -0.135 | -0.00200 | 0.152 | 0.318 | 5.123 | L1 | C18 |
| 553 | Shodex C18-4D | Showa Denko | B | 1.01 | 0.0270 | 0.0210 | -0.0100 | -0.110 | 0.107 | 8.207 | L1 | C18 |
| 554 | Venusil HLP | Bonna-Agela Technologies, Inc. | EP | 0.547 | -0.0150 | -0.649 | 0.254 | -0.926 | 1.64 | 3.801 | L60 | EP |
| 555 | Venusil XBP CN | Bonna-Agela Technologies, Inc. | CN | 0.450 | -0.0530 | -0.631 | -0.0130 | -0.0180 | 0.737 | 1.94 | L10 | CN |
| 556 | Zodiac C18(1) | Zodiac Life Sciences | B | 0.973 | 0.00800 | -0.124 | 0.0190 | 0.204 | 0.156 | 5.091 | L1 | C18 |
| 557 | Zodiac C18 | Zodiac Life Sciences | B | 1.07 | 0.0520 | -0.0690 | -0.0390 | -0.184 | -0.152 | 11.626 | L1 | C18 |
| 558 | Kinetex Phenyl-Hexyl | Phenomenex | phenyl | 0.795 | -0.0910 | -0.258 | 0.0160 | 0.0620 | 0.236 | 3.49 | L11 | Phenyl |
| 559 | Ultimate XB-C18 | Welch | B | 1.01 | 0.0110 | -0.0460 | 0.00100 | 0.118 | 0.133 | 9.39 | L1 | C18 |
| 560 | Ultimate XB-C8 | Welch | B | 0.835 | 0.00100 | -0.0740 | 0.0280 | 0.0690 | 0.281 | 5.55 | L7 | C8 |
| 561 | Ultimate XB-Phenyl | Welch | phenyl | 0.651 | -0.108 | -0.250 | 0.0320 | 0.150 | 0.476 | 3.45 | L11 | Phenyl |
| 562 | Xselect HSS Cyano | Waters | CN | 0.479 | -0.116 | -0.224 | 0.0430 | 0.0820 | 1.18 | 1.76 | L10 | CN |
| 563 | Ultisil XB-Phenyl | Welch | phenyl | 0.651 | -0.108 | -0.273 | 0.0320 | 0.144 | 0.466 | 3.53 | L11 | Phenyl |
| 564 | Ultisil XB-C8 | Welch | B | 0.841 | 0.00100 | -0.108 | 0.0270 | 0.0630 | 0.244 | 5.87 | L7 | C8 |
| 565 | Ultisil XB-C18 | Welch | B | 1.01 | 0.0120 | -0.0160 | 0.00500 | 0.118 | 0.142 | 9.44 | L1 | C18 |
| 566 | Ultisil AQ-C18 | Welch | B | 0.872 | -0.0370 | -0.0720 | 0.0310 | 0.0540 | 0.323 | 6.61 | L1 | C18 |
| 567 | Xtimate C8 | Welch | B | 0.855 | -0.0140 | -0.185 | 0.00800 | 0.0130 | 0.173 | 6.26 | L7 | C8 |
| 568 | Xtimate C18 | Welch | B | 1.00 | -0.00100 | -0.0830 | -0.0110 | 0.155 | 0.283 | 8.99 | 1 | C18 |
| 569 | Ultimate AQ-C18 | Welch | B | 0.868 | -0.0330 | -0.0550 | 0.0290 | 0.0580 | 0.363 | 6.51 | L1 | C18 |
| 570 | Topsil C18 | Welch | B | 0.972 | -0.0110 | -0.0190 | 0.00900 | 0.124 | 0.312 | 7.37 | L1 | C18 |
| 571 | Chromolith Performance RP-8e | Merck KGaA (EMD Millipore)Ê | B | 0.833 | -0.0140 | -0.0100 | 0.0140 | 0.0710 | 0.572 | 2.41 | L7 | C8 |
| 572 | Chromolith HighResolution RP-18e | Merck KGaA (EMD Millipore)Ê | B | 0.999 | 0.0190 | 0.0170 | -0.00100 | 0.206 | 0.285 | 3.41 | L1 | C18 |
| 573 | Cosmicsil Aura ODS | Genius Technologies | B | 0.948 | -0.0400 | -0.185 | 0.00900 | -0.0470 | 0.0890 | 11.7 | L1 | C18 |
| 574 | Cosmicsil AQ C18 120 | Genius Technologies | B | 0.958 | -0.0390 | -0.0720 | 0.0130 | 0.133 | 0.295 | 9.19 | L1 | C18 |
| 575 | Cosmicsil Aster C18 XD | Genius Technologies | B | 1.08 | 0.0380 | 0.0420 | -0.0240 | -0.0860 | 0.0840 | 13.5 | L1 | C18 |
| 576 | Cosmicsil Agate 100 C18 | Genius Technologies | B | 1.02 | -0.0260 | -0.0700 | 0.00900 | 0.0480 | 0.263 | 13 | L1 | C18 |
| 577 | Cosmicsil Adore 100 CN | Genius Technologies | B | 0.339 | -0.0670 | -0.488 | 0.00800 | 0.0990 | 0.901 | 0.561 | L10 | CN |
| 578 | Symmetry C4 | Waters | B | 0.687 | -0.0120 | -0.290 | 0.0220 | 0.217 | 0.305 | 1.41 | L26 | C4 |
| 579 | Shim-pack XR-ODS II | Shimadzu | B | 1.09 | 0.0390 | 0.0760 | -0.0260 | -0.00600 | 0.204 | 12.85 | L1 | C18 |
| 580 | Xselect HSS PFP | Waters | F | 0.592 | -0.164 | 0.146 | -0.0200 | 0.740 | 1.77 | 3.35 | L43 | F |
| 581 | Nucleodur PAH C18 | Macherey Nagel | B | 1.01 | 0.00800 | 0.574 | -0.0220 | 0.343 | 1.22 | 8.74 | L1 | C18 |
| 582 | Nucleodur POLARTEC C18 | Macherey Nagel | B | 0.858 | 0.168 | -0.259 | 0.351 | -3.40 | -0.787 | 7.67 | L1 | C18 |
| 583 | Monitor C18 | Orochem | B | 0.981 | -0.00400 | -0.131 | 0.00100 | 0.0210 | 0.0630 | 9.13 | L1 | C18 |
| 584 | Matrix C18 | Orochem | B | 0.934 | -0.0460 | 0.0680 | -0.00300 | 0.0710 | 0.765 | 11.42 | L1 | C18 |
| 585 | Orosil C18 | Orochem | B | 0.981 | -0.0320 | -0.137 | 0.00200 | -0.0480 | 0.155 | 12.61 | L1 | C18 |
| 586 | Polar C18 | Orochem | B | 1.04 | -0.0860 | 0.645 | -0.0350 | 1.07 | 1.56 | 10.17 | L1 | C18 |
| 587 | Reliasil C18 | Orochem | B | 0.879 | -0.00400 | 0.326 | 0.0480 | 0.592 | 0.822 | 8.97 | L1 | C18 |
| 588 | InertSustain C8 | GL Sciences | B | 0.868 | -0.00500 | -0.270 | -0.0210 | -0.0350 | -0.122 | 8.59 | L7 | C8 |
| 589 | InertSustain Phenyl | GL Sciences | phenyl | 0.569 | -0.135 | -0.375 | 0.0350 | -0.0440 | 0.320 | 3.37 | L11 | Phenyl |
| 590 | Nucleoshell RP 18 | Macherey Nagel | B | 1.11 | 0.0360 | 0.0770 | -0.0400 | 0.0820 | 0.266 | 7.5 | L1 | C18 |
| 591 | Nucleodur HTEC C18 | Macherey Nagel | B | 1.05 | 0.0380 | -0.0220 | -0.0150 | -0.482 | 0.136 | 11.7 | L1 | C18 |
| 592 | Nucleodur PFP | Macherey Nagel | F | 0.712 | -0.0590 | -0.265 | -0.0360 | 0.0230 | 0.810 | 4.8 | L43 | F |
| 593 | Balancil C18 | Bonna-Agela Technologies, Inc. | B | 0.918 | -0.0370 | -0.170 | 0.0250 | 0.109 | 0.734 | 7.97 | L1 | C18 |
| 594 | Venusil XBP Phenyl-Hexyl | Bonna-Agela Technologies, Inc. | phenyl | 0.678 | -0.170 | 0.128 | 0.0340 | 0.156 | 1.20 | 5.487 | L11 | Phenyl |
| 595 | Venusil PFP | Bonna-Agela Technologies, Inc. | F | 0.519 | -0.158 | 0.120 | 0.0110 | 0.350 | 1.14 | 2.763 | L43 | F |
| 596 | Venusil XBP Polar-Phenyl | Bonna-Agela Technologies, Inc. | phenyl | 0.552 | -0.214 | 0.0160 | 0.0520 | -0.0340 | 1.07 | 3.19 | L11 | Phenyl |
| 597 | Promosil C18 | Bonna-Agela Technologies, Inc. | B | 1.06 | 0.0360 | -0.0680 | -0.0120 | -0.00200 | -0.0900 | 11.533 | L1 | C18 |
| 598 | Venusil XBP Phenyl | Bonna-Agela Technologies, Inc. | phenyl | 0.626 | -0.118 | -0.234 | 0.0200 | 0.0240 | 0.776 | 4.151 | L11 | Phenyl |
| 599 | Halo 5 C18 | Advanced Materials Technology | B | 1.15 | 0.0550 | 0.0250 | -0.0550 | 0.0730 | 0.100 | 7.031 | L1 | C18 |
| 600 | Halo ES-CN | Advanced Materials Technology | B | 0.566 | -0.110 | -0.344 | 0.0210 | 0.126 | 1.15 | 1.88 | L10 | CN |
| 601 | Halo 5 PFP | Advanced Materials Technology | B | 0.711 | -0.122 | -0.0700 | -0.0520 | 1.16 | 1.85 | 2.725 | L43 | F |
| 602 | Athena C8 | CNW Technologies | B | 0.831 | -0.0210 | -0.166 | 0.00900 | 0.0260 | 0.274 | 6.43 | L7 | C8 |
| 603 | Athena C18 | CNW Technologies | B | 0.997 | 0.00200 | -0.0300 | -0.0130 | 0.0940 | 0.265 | 9.82 | L1 | C18 |
| 604 | Athena C18-WP | CNW Technologies | B | 0.953 | -0.0300 | -0.203 | -0.00300 | -0.0520 | 0.0660 | 11.1 | L1 | C18 |
| 605 | Athena Phenyl | CNW Technologies | phenyl | 0.587 | -0.114 | -0.396 | 0.0330 | 0.0670 | 0.345 | 2.52 | L11 | Phenyl |
| 606 | Cosmicsil Adze C18 | Genius Technologies | B | 0.997 | -0.0190 | -0.138 | -0.0130 | -0.0820 | 0.0690 | 12.7 | L1 | C18 |
| 607 | Cosmicsil BDS C18 | Genius Technologies | B | 0.854 | -0.0350 | 0.195 | -0.0120 | 0.476 | 0.929 | 3.79 | L1 | C18 |
| 608 | Syncronis C18 | Thermo/Hypersil | B | 1.04 | -0.00300 | -0.0860 | -0.0190 | -0.0260 | 0.0380 | 13 | L1 | C18 |
| 609 | Syncronis C8 | Thermo/Hypersil | B | 0.840 | -0.0240 | -0.227 | 0.0100 | -0.0580 | 0.116 | 7.99 | L7 | C8 |
| 610 | Syncronis aQ | Thermo/Hypersil | EP | 0.984 | -0.00400 | -0.100 | -0.0380 | 0.0660 | 1.08 | 10.2 | L60 | EP |
| 611 | Syncronis Phenyl | Thermo/Hypersil | phenyl | 0.750 | -0.0820 | -0.320 | 0.00800 | -0.0310 | 0.176 | 6.36 | L11 | Phenyl |
| 612 | Hypersil GOLD C4 | Thermo/Hypersil | B | 0.705 | -0.00300 | -0.285 | 0.0260 | 0.110 | 0.235 | 2.19 | L26 | C4 |
| 613 | Hypersil GOLD Phenyl | Thermo/Hypersil | phenyl | 0.650 | -0.0910 | -0.362 | 0.0300 | 0.161 | 0.416 | 2 | L11 | Phenyl |
| 614 | Hypersil GOLD CN | Thermo/Hypersil | CN | 0.397 | -0.0350 | -0.886 | -0.0190 | -0.0690 | 0.660 | 0.75 | L10 | CN |
| 615 | Accucore XL C18 | Thermo/Hypersil | B | 1.09 | 0.0590 | 0.0510 | -0.0380 | 0.0860 | 0.384 | 5.22 | L1 | C18 |
| 616 | Accucore XL C8 | Thermo/Hypersil | B | 0.926 | 0.0200 | -0.161 | -0.00100 | 0.0200 | -0.432 | 4.63 | L7 | C8 |
| 617 | Accucore C18 | Thermo/Hypersil | B | 1.09 | 0.0540 | 0.0550 | -0.0400 | 0.0720 | 0.0950 | 6.5 | L1 | C18 |
| 618 | Accucore C8 | Thermo/Hypersil | B | 0.924 | 0.0150 | -0.0840 | -0.00300 | 0.00200 | 0.186 | 5.2 | L7 | C8 |
| 619 | Accucore C30 | Thermo/Hypersil | B | 0.978 | -0.0200 | -0.143 | -0.00200 | 0.321 | 0.462 | 4.52 | L62 | C30 |
| 620 | Accucore 150-C18 | Thermo/Hypersil | B | 1.03 | 0.0460 | -0.0370 | -0.00900 | 0.200 | 0.171 | 4.45 | L1 | C18 |
| 621 | Accucore 150-C4 | Thermo/Hypersil | B | 0.738 | -0.00800 | -0.309 | 0.0230 | 0.130 | 0.224 | 2.17 | L26 | C4 |
| 622 | Accucore aQ | Thermo/Hypersil | EP | 1.07 | 0.0500 | 0.00200 | -0.0590 | 0.0600 | 0.508 | 5.46 | L60 | EP |
| 623 | Accucore Phenyl-X | Thermo/Hypersil | phenyl | 0.781 | -0.103 | -0.554 | 0.0440 | -0.294 | -0.0820 | 3.64 | L11 | Phenyl |
| 624 | Accucore Phenyl-Hexyl | Thermo/Hypersil | phenyl | 0.786 | -0.0470 | -0.223 | 0.00600 | 0.0550 | 0.574 | 3.6 | L11 | Phenyl |
| 625 | Accucore PFP | Thermo/Hypersil | F | 0.729 | -0.0980 | -0.249 | -0.0360 | 0.873 | 1.66 | 3.22 | L43 | F |
| 626 | Accucore RP-MS | Thermo/Hypersil | B | 1.00 | 0.0240 | -0.0150 | -0.00600 | 0.0270 | 0.0570 | 6.2 | | |
| 627 | Accucore Polar Premium | Thermo/Hypersil | EP | 0.871 | 0.103 | -0.567 | 0.217 | -0.207 | 0.787 | 5.6 | L60 | EP |
| 628 | Acclaim C30 | Thermo/Hypersil | B | 0.973 | -0.0220 | -0.126 | 0.00400 | 0.353 | 0.320 | 5.52 | L62 | C30 |
| 629 | Acclaim Phenyl-1 | Thermo/Hypersil | phenyl | 0.689 | -0.150 | -0.548 | 0.0680 | 0.0130 | 0.150 | 4.27 | L11 | Phenyl |
| 630 | Ascentis Express F5 | Supelco | F | 0.721 | -0.124 | 0.0670 | -0.0740 | 1.06 | 1.84 | 3.25 | L43 | F |
| 631 | Ascentis Express 5 F5 | Supelco | F | 0.711 | -0.118 | -0.0970 | -0.0670 | 1.06 | 1.71 | 2.85 | L43 | F |
| 632 | Ascentis Express 5 C18 | Supelco | B | 1.13 | 0.0530 | 0.0530 | -0.0500 | 0.0840 | 0.197 | 6.56 | L1 | C18 |
| 633 | Halo 5 C8 | Advanced Materials Technology | B | 0.920 | 0.0170 | -0.118 | -0.00200 | -0.00200 | 0.205 | 4.6 | L7 | C8 |
| 634 | Halo 5 Phenyl-Hexyl | Advanced Materials Technology | B | 0.799 | -0.0910 | -0.295 | -0.00400 | 0.115 | 0.429 | 3.29 | L11 | Phenyl |
| 635 | Ascentis Express ES-CN | Supelco | CN | 0.565 | -0.0980 | -0.415 | 0.0140 | 0.0310 | 1.04 | 1.88 | L10 | CN |
| 636 | Halo 5 ES-CN | Advanced Materials Technology | B | 0.558 | -0.102 | -0.492 | 0.0120 | 0.0810 | 0.967 | 1.61 | L10 | CN |
| 637 | Poroshell 120 EC-C18 | Agilent Technologies | B | 1.02 | 0.00800 | -0.130 | -0.00400 | 0.161 | 0.123 | 6.92 | L1 | C18 |
| 638 | Poroshell 120 EC-C8 | Agilent Technologies | B | 0.877 | 0.0110 | -0.232 | 0.0230 | 0.127 | 0.0900 | 4.84 | L7 | C8 |
| 639 | Poroshell 120 EC-CN | Agilent Technologies | CN | 0.421 | -0.0570 | -0.476 | 0.00200 | 0.0450 | 0.870 | 0.95 | L10 | CN |
| 640 | Poroshell 120 Phenyl-Hexyl | Agilent Technologies | phenyl | 0.752 | -0.0830 | -0.394 | 0.0180 | 0.136 | 0.140 | 3.59 | L11 | Phenyl |
| 641 | Poroshell 120 Bonus-RP | Agilent Technologies | EP | 0.686 | -0.0300 | -0.573 | 0.180 | -0.670 | -0.0170 | 3.98 | L60 | EP |
| 642 | Poroshell 120 SB-C18 | Agilent Technologies | B | 0.956 | -0.0410 | 0.168 | 0.0250 | 0.210 | 0.763 | 5.44 | L1 | C18 |
| 643 | Poroshell 120 SB-C8 | Agilent Technologies | B | 0.726 | -0.0870 | 0.0680 | 0.0440 | 0.0870 | 0.807 | 3.56 | L7 | C8 |
| 644 | Poroshell 120 SB-AQ | Agilent Technologies | EP | 0.581 | -0.120 | -0.133 | 0.0510 | -0.0140 | 0.670 | 2.15 | L60 | EP |
| 645 | Titan C18 | Supelco | C18 | 1.01 | 0.00400 | -0.0840 | -0.0470 | -0.0520 | 0.0880 | 10.11 | L1 | C18 |
| 646 | Cosmosil piNap | Nacalai Tesque | phenyl | 0.665 | -0.176 | -0.258 | 0.0340 | 0.188 | 0.789 | 3.48 | L11 | phenyl |
| 647 | Cosmosil 5PYE | Nacalai Tesque | Other | 0.671 | -0.271 | -0.283 | 0.0920 | 0.521 | 1.32 | 3.81 | | Other |
| 648 | Excel SuperC18 | ACT | C18 | 0.997 | -0.00300 | -0.201 | -0.0130 | 0.0300 | 0.00900 | 9.92 | L1 | C18 |
| 649 | Excel CN-ES | ACT | CN | 0.811 | -0.00500 | -0.429 | -0.0100 | -0.0520 | 0.153 | 3.74 | L10 | CN |
| 650 | Excel C18-Amide | ACT | EP | 0.791 | 0.0230 | -0.489 | 0.199 | -0.0600 | 0.176 | 5.86 | | EP |
| 651 | UltraCore SuperPhenylHexyl | ACT | phenyl | 0.809 | -0.0740 | -0.347 | -0.0140 | -0.0140 | -0.00700 | 3.7 | L11 | phenyl |
| 652 | Ultracore SuperC18 | ACT | B | 1.09 | 0.0300 | -0.111 | -0.0500 | -0.0290 | 0.0280 | 6.92 | L1 | C18 |
| 653 | Flare C18 | Diamond Analytics | Other | 0.806 | -0.0730 | -0.470 | 0.841 | -1.48 | 2.41 | 0.75 | | Other |
| 654 | Cosmicsil Agate RP C8 | Genius Technologies | B | 0.846 | -0.00800 | -0.178 | 0.0220 | 0.0340 | 0.262 | 7.16 | L7 | C8 |
| 655 | Cosmicsil APT C18 | Genius Technologies | B | 1.02 | 0.00400 | -0.0640 | -0.00700 | 0.135 | 0.196 | 10.43 | L1 | C18 |
| 656 | Cosmicsil Glory C18 | Genius Technologies | B | 1.00 | 0.00700 | -0.170 | 0.00300 | 0.172 | 0.222 | 9.38 | L1 | C18 |
| 657 | Cosmicsil Abra C18 | Genius Technologies | B | 0.810 | 0.0310 | -0.482 | 0.214 | -0.178 | 0.139 | 8.16 | L1 | C18 |
| 658 | Cosmicsil Agate RP C18 | Genius Technologies | B | 1.02 | 0.0170 | -0.00700 | -0.00700 | 0.185 | 0.230 | 10.61 | L1 | C18 |
| 659 | Kinetex Biphenyl 100A | Phenomenex | phenyl | 0.697 | -0.173 | -0.583 | 0.0340 | 0.122 | 0.817 | 2.63 | L11 | Phenyl |
| 660 | Aeris WIDEPORE XB-C8 | Phenomenex | B | 0.788 | -0.0380 | -0.169 | 0.0730 | -0.0420 | 0.518 | 1.23 | L7 | C8 |
| 661 | Aeris WIDEPORE XB-C18 | Phenomenex | B | 0.934 | -0.0320 | -0.134 | 0.0680 | 0.0730 | 0.360 | 1.81 | L1 | C18 |
| 662 | Aeris WIDEPORE XB-C4 | Phenomenex | B | 0.699 | -0.0210 | -0.310 | 0.0170 | 0.0840 | 0.195 | 0.91 | L26 | C4 |
| 663 | Aeris PEPTIDE XB-C18 | Phenomenex | B | 0.992 | -0.0210 | -0.0950 | 0.0160 | 0.0710 | 0.314 | 5.65 | L1 | C18 |
| 664 | Primesep A | SIELC | Other | 0.570 | -0.199 | 0.0570 | 0.0320 | 2.73 | 2.60 | 1.57 | | Other |
| 665 | Primesep B | SIELC | Other | 0.497 | -0.00400 | 0.0340 | 0.584 | -1.87 | -1.36 | 0.91 | | Other |
| 666 | Primesep C | SIELC | Other | 0.513 | -0.146 | -0.265 | 0.124 | 1.04 | 1.55 | 1.85 | | Other |
| 667 | Cortecs C18 | Waters | B | 1.08 | 0.0430 | -0.108 | -0.0370 | 0.0630 | 0.0350 | 6.39 | L1 | C18 |
| 668 | Cortecs C18+ | Waters | B | 1.04 | -0.00500 | 0.175 | 0.0260 | -0.0330 | 0.537 | 6.54 | L1 | C18 |
| 669 | Sunshell RP-AQUA | Chromanik | C28 | 0.898 | -0.0400 | -0.272 | 0.0130 | 0.127 | 0.0950 | 4.02 | L62 | C28 |
| 670 | Sunshell C18 | Chromanik | B | 1.09 | 0.0280 | -0.124 | -0.0560 | -0.0430 | -0.0840 | 7.79 | L1 | C18 |
| 671 | Sunshell Phenyl | Chromanik | phenyl | 0.813 | -0.0760 | -0.323 | -0.0170 | -0.0610 | -0.0900 | 4.161 | L11 | Phenyl |
| 672 | Sunshell C8 | Chromanik | B | 0.907 | 0.00700 | -0.235 | -0.0280 | -0.0650 | -0.126 | 4.7 | L7 | C8 |
| 673 | Sunshell PFP | Chromanik | fluoro | 0.663 | -0.176 | 0.140 | -0.0760 | 1.11 | 2.14 | 2.46 | L43 | F |
| 674 | Sunniest C8 | Chromanik | B | 0.845 | 0.00500 | -0.304 | -0.00200 | 0.0360 | -0.0180 | 5.7 | L7 | C8 |
| 675 | Sunniest PhE | Chromanik | phenyl | 0.656 | -0.0850 | -0.469 | 0.00800 | 0.0440 | -0.0220 | 3.24 | L11 | Phenyl |
| 676 | Sunniest RP-AQUA | Chromanik | C28 | 0.958 | -0.0240 | -0.210 | -0.00800 | 0.142 | 0.0980 | 8.49 | L62 | C28 |
| 677 | Sunniest C18 | Chromanik | B | 1.02 | 0.0100 | -0.169 | -0.0230 | 0.0890 | 0.803 | 9.62 | L1 | C18 |
| 678 | Sunniest PFP | Chromanik | fluoro | 0.615 | -0.150 | -0.0490 | -0.0400 | 1.10 | 1.80 | 2.97 | L43 | F |
| 679 | Kinetex EVO C18 | Phenomenex | B | 1.01 | -0.00600 | -0.170 | -0.0240 | -0.110 | -0.0100 | 4.38 | L1 | C18 |
| 680 | Flare C18+ | Diamond Analytics | Other | 1.14 | -0.310 | 0.730 | 0.970 | -0.510 | 1.20 | 0.27 | | Other |
| 681 | Primesil C8 | Wesley Technologies Inc | B | 0.857 | -0.0140 | -0.200 | 0.0180 | -0.0520 | 0.170 | 8.2 | L7 | C8 |
| 682 | Primesil C18 5 micron | Wesley Technologies Inc | B | 1.04 | -0.00200 | -0.0430 | -0.0130 | 0.0150 | 0.150 | 12.4 | L1 | C18 |
| 683 | Primesil C18 3 micron | Wesley Technologies Inc | B | 1.02 | 0.0250 | -0.0600 | -0.00100 | 0.0140 | 0.120 | 9 | L1 | C18 |
| 684 | Primesil ODS-P | Wesley Technologies Inc | EP | 0.752 | 0.0900 | -0.670 | 0.0420 | -0.240 | -0.0150 | 8.7 | L60 | EP |
| 685 | Primesil C18-2 | Wesley Technologies Inc | B | 1.00 | -0.00400 | -0.0570 | -0.00600 | 0.109 | 0.180 | 10.3 | L1 | C18 |
| 686 | Kinetex F5 | Phenomenex | fluoro | 0.725 | -0.0640 | -0.320 | -0.0460 | 0.110 | 2.66 | 3.03 | L43 | F |
| 687 | Selectra Aqueous C18 | UCT | B | 0.780 | -0.110 | 0.0110 | 0.0110 | 0.0760 | 1.15 | 6.79 | L60 | EP |
| 688 | Selectra C18 | UCT | B | 1.05 | 0.0320 | 0.00600 | -0.0170 | 0.0150 | 0.0260 | 11.8 | L1 | C18 |
| 689 | Selectra PFPP | UCT | fluoro | 0.674 | -0.0810 | -0.330 | -0.0330 | 0.430 | 1.26 | 4.63 | L43 | F |
| 690 | InertSustain AQ-C18 | GL Sciences | B | 0.939 | -0.0500 | -0.230 | 0.00100 | -0.00300 | -0.0950 | 10.7 | L1 | C18 |
| 691 | InertSustain Phenylhexyl | GL Sciences | phenyl | 0.743 | -0.0430 | -0.370 | -0.0150 | -0.109 | -0.204 | 5.92 | L11 | Phenyl |
| 692 | InertSustainSwift C18 | GL Sciences | B | 0.882 | -0.0130 | -0.310 | -0.00100 | 0.130 | 0.0740 | 4.74 | L1 | C18 |
| 693 | Poroshell 120 HPH C8 | Agilent Technologies | B | 0.887 | 0.0100 | -0.250 | 0.00800 | -0.0190 | -0.0730 | 4.18 | L7 | C8 |
| 694 | Poroshell 120 HPH C18 | Agilent Technologies | B | 1.03 | 0.00500 | -0.140 | -0.0140 | 0.0730 | -0.00400 | 6.1 | L1 | C18 |
| 695 | Poroshell 120 PFP | Agilent Technologies | fluoro | 0.630 | -0.0590 | -0.460 | 0.0150 | -0.0380 | 0.741 | 2.88 | L43 | F |
| 696 | Ascentis Express Biphenyl | Supelco | phenyl | 0.702 | -0.177 | -0.230 | 0.0310 | 0.208 | 0.923 | 2.43 | L11 | phenyl |
| 697 | Acquity UPLC BEH C18 | Waters | B | 1.00 | 0.0280 | -0.366 | 0.00700 | 0.142 | 0.0880 | 6.4 | L1 | C18 |
| 698 | Acquity UPLC CSH C18 | Waters | EP | 0.968 | 0 | -0.355 | 0.199 | 0.0650 | 0.157 | 6.1 | L60 | EP |
| 699 | YMC-Triart C8 | YMC | B | 0.830 | -0.00700 | -0.317 | -0.00700 | -0.0230 | -0.102 | 7.2 | L7 | C8 |
| 700 | YMC-Triart C18 ExRS | YMC | B | 1.17 | 0.0630 | -0.00400 | -0.0960 | -0.139 | -0.254 | 18.4 | L1 | C18 |
| 701 | YMC-Triart Phenyl | YMC | phenyl | 0.723 | -0.0720 | -0.376 | -0.00800 | -0.0210 | -0.0840 | 5.3 | L11 | phenyl |
| 702 | YMC-Triart PFP | YMC | fluoro | 0.586 | -0.182 | -0.0140 | -0.0450 | 0.363 | 1.36 | 3.8 | L43 | F |
| 703 | BIOshell A160 Peptide C18 | Supelco | B | 0.890 | -0.0590 | 0.250 | 0.0240 | 0.177 | 0.819 | 3 | L1 | C18 |
| 704 | BIOshell A400 Protein C18 | Supelco | B | 0.940 | -0.0520 | -0.202 | 0.0630 | 0.177 | 0.261 | 1.1 | L1 | C18 |
| 705 | BIOshell A400 Protein C4 | Supelco | B | 0.704 | 0.00500 | -0.847 | 0.0130 | 0.109 | 0.155 | 0.61 | L26 | C4 |
| 706 | BIOshell A160 Peptide CN | Supelco | CN | 0.481 | -0.0980 | -0.353 | 0.0280 | 0.0760 | 0.838 | 0.9 | L10 | CN |
| 707 | Luna Omega C18 | Phenomenex | B | 0.976 | -0.00290 | -0.187 | -0.00710 | -0.0180 | 0.00500 | 9.6 | L1 | C18 |
| 708 | Luna Omega Polar C18 | Phenomenex | EP | 0.860 | -0.0700 | -0.158 | 0.0200 | 0.00270 | 0.558 | 7.4 | L60 | EP |
| 709 | Luna Omega PS C18 | Phenomenex | EP | 0.901 | -0.0170 | -0.273 | 0.0110 | -0.290 | 0.0130 | 7.6 | L60 | EP |
| 710 | Halo AQ-C18 | Advanced Materials Technology | B | 1.00 | -0.0360 | 0.0990 | -0.0480 | 0.156 | 0.864 | 6.7 | L1 | C18 |
| 711 | Halo Biphenyl | Advanced Materials Technology | B | 0.708 | -0.183 | -0.279 | 0.0280 | 0.0470 | 0.990 | 3.1 | L11 | phenyl |
| 712 | Svea C18 | Nanologica | B | 1.06 | 0.0410 | -0.0540 | -0.0280 | 0.0470 | -0.0310 | 11.2 | L1 | C18 |
| 713 | Svea PheHex | Nanologica | phenyl | 0.763 | -0.0900 | -0.304 | 0.0110 | 0.152 | 0.417 | 5.5 | L11 | phenyl |
| 714 | Svea C4 | Nanologica | B | 0.730 | -0.00200 | -0.289 | 0.0170 | 0.0420 | 0.304 | 4.6 | L26 | C4 |
| 715 | Kanak C18 | Nanghavi Chromatography Solutions Ltd | B | 1.06 | 0.0410 | -0.0540 | -0.0280 | 0.0470 | -0.0310 | 11.2 | L1 | C18 |
| 716 | Kanak PheHex | Nanghavi Chromatography Solutions Ltd | phenyl | 0.763 | -0.0900 | -0.304 | 0.0110 | 0.152 | 0.417 | 5.5 | L11 | phenyl |
| 717 | Kanak C4 | Nanghavi Chromatography Solutions Ltd | B | 0.730 | -0.00200 | -0.289 | 0.0170 | 0.0420 | 0.304 | 4.6 | L26 | C4 |
| 718 | Cortecs C8 | Waters | B | 0.882 | 0.0200 | -0.210 | -0.00700 | 0.0280 | 0.0470 | 4.5 | L7 | C8 |
| 719 | Cortecs T3 | Waters | B | 0.954 | -0.0360 | -0.160 | 0.0160 | 0.150 | 0.190 | 5.2 | L1 | C18 |
| 720 | Cortecs Phenyl | Waters | phenyl | 0.764 | -0.0880 | -0.310 | 0.00900 | 0.0420 | 0.590 | 3.3 | L11 | phenyl |
| 721 | Cortecs UPLC Shield RP18 | Waters | EP | 0.869 | -0.0230 | -0.280 | 0.100 | -0.190 | 0.0960 | 4.9 | L60 | EP |
| 722 | Xbridge Protein BEH C4 | Waters | B | 0.546 | -0.0730 | -0.210 | 0.0430 | 0.00700 | 0.120 | 0.85 | L26 | C4 |
| 723 | BioResolve RP mAb | Waters | phenyl | 0.586 | -0.140 | -0.490 | 0.0580 | 0.180 | 0.250 | 0.39 | L11 | phenyl |
| 724 | Inertsil ODS-HL | GL Sciences | B | 1.07 | 0.0100 | -0.0370 | -0.0660 | 0.0160 | -0.0130 | 16 | L1 | C18 |
| 725 | InertSustainSwift C8 | GL Sciences | B | 0.785 | -0.0140 | -0.320 | 0 | 0.0700 | 0 | 3.7 | L7 | C8 |
| 726 | InertSustain Cyano | GL Sciences | CN | 0.445 | -0.0400 | -0.370 | -0.0150 | -0.0770 | 0.830 | 1.6 | L10 | CN |
| 727 | Svea C8 | Nanologica | B | 0.873 | 0.0140 | -0.170 | 0.0120 | 0.0290 | 0.150 | 7.2 | L7 | C8 |
| 728 | Svea PFP | Nanologica | fluoro | 0.633 | -0.0850 | -0.260 | 0.0240 | 0.400 | 1.28 | 3.7 | L43 | F |
| 729 | Svea CN | Nanologica | CN | 0.440 | -0.0460 | -0.650 | -0.0100 | 0.0100 | 0.820 | 1.6 | L10 | CN |
| 730 | Halo C30 | Advanced Materials Technology | B | 0.938 | -0.0460 | -0.140 | 0.0230 | 0.170 | 0.350 | 4.5 | L62 | C30 |
| 731 | Ultimate LP-C18 | Welch | B | 0.913 | -0.0440 | 0.160 | 0.0260 | 0.150 | 0.770 | 7.4 | L1 | C18 |
| 732 | Ultimate Plus C18 | Welch | B | 0.979 | -0.00300 | -0.120 | 0.0150 | 0.160 | 0.170 | 6.3 | L1 | C18 |
| 733 | Ultimate XS-C18 | Welch | B | 0.982 | -0.00900 | 0.450 | -0.0160 | 0.220 | 1.20 | 9.5 | L1 | C18 |
| 734 | Ultimate Polar-RP | Welch | B | 0.773 | 0.0260 | -0.430 | 0.190 | -0.270 | 0.100 | 6.4 | L60 | EP |
| 735 | Ultimate PFP | Welch | fluoro | 0.636 | -0.100 | -0.170 | -0.0230 | 0.450 | 1.10 | 3.4 | L43 | F |
| 736 | Ultimate XB-CN | Welch | CN | 0.394 | -0.0740 | -0.300 | 0.00700 | 0.0920 | 0.920 | 1.1 | L10 | CN |
| 737 | Ultisil LP-C18 | Welch | B | 0.916 | -0.0420 | 0.150 | 0.0260 | 0.140 | 0.760 | 7.6 | L1 | C18 |
| 738 | Ultisil Polar-RP | Welch | B | 0.773 | 0.0280 | -0.440 | 0.190 | -0.250 | 0.0370 | 6.4 | L60 | EP |
| 739 | Primesil C8 | Wesley Technologies Inc | B | 0.858 | 0.00900 | -0.186 | 0.0260 | 0.100 | 0.125 | 6.3 | L7 | C8 |
| 740 | Flowrosil ODS | Wesley Technologies Inc | B | 1.01 | 0.00400 | -0.121 | 0 | 0.162 | 0.142 | 9.5 | L1 | C18 |
| 741 | Flowrosil C18 AQ | Wesley Technologies Inc | B | 0.894 | -0.0400 | -0.182 | 0.0240 | 0.112 | 0.171 | 7.5 | L1 | C18 |
| 742 | Flowrosil C8 | Wesley Technologies Inc | B | 0.857 | 0.00100 | -0.173 | 0.0240 | 0.110 | 0.166 | 6.4 | L7 | C8 |
| 743 | Targetsil C18 HPH | Wesley Technologies Inc | B | 0.973 | -0.0140 | -0.0840 | 0.0100 | 0.148 | 0.208 | 7.2 | L1 | C18 |
| 744 | Targetsil C18 Polar | Wesley Technologies Inc | B | 0.778 | 0.0170 | -0.463 | 0.185 | -0.301 | 0.0180 | 7 | L1 | C18 |
| 745 | VDSpher PUR 100 C18-E | VDS Optilab | B | 1.03 | -0.00340 | -0.00260 | -0.0160 | 0.0100 | 0.150 | 13 | L1 | C18 |
| 746 | VDSpher PUR 100 C18-H | VDS Optilab | B | 0.809 | -0.0730 | -0.140 | 0.0150 | 0.0330 | 0.970 | 7.8 | L1 | C18 |
| 747 | VDSpher PUR 100 C18-M-SE | VDS Optilab | B | 1.07 | 0.0370 | -0.0440 | -0.0370 | -0.0600 | 0.0220 | 13.1 | L1 | C18 |
| 748 | VDSpher PUR 100 C18-M | VDS Optilab | B | 0.903 | -0.0770 | 0.510 | 0.000200 | 0.120 | 1.51 | 10.2 | L1 | C18 |
| 749 | Triart Bio C4 | YMC | B | 0.673 | -0.0150 | -0.350 | 0.0200 | 0.130 | 0.0640 | 1.2 | L26 | C4 |
| 750 | Shim-pack Arata C18 | Shimadzu | B | 0.782 | 0.0320 | -0.503 | 0.236 | -0.520 | 0.0790 | 7.6 | L1 | C18 |
| 751 | Shim-pack Velox SP-C18 | Shimadzu | B | 0.983 | -0.0450 | 0.385 | 0.0100 | 0.106 | 1.06 | 6.3 | L1 | C18 |
| 752 | Shim-pack Velox C18 | Shimadzu | B | 1.10 | 0.0510 | 0.101 | -0.0340 | 0.111 | 0.196 | 6.6 | L1 | C18 |
| 753 | Shim-pack Velox Biphenyl | Shimadzu | B | 0.707 | -0.190 | -0.244 | 0.0460 | 0.0630 | 1.07 | 3.2 | L11 | phenyl |
| 754 | Shim-pack Velox PFPP | Shimadzu | B | 0.688 | -0.130 | 0.116 | -0.0430 | 0.443 | 1.59 | 3 | L43 | F |
| 755 | Betasil C18 | Thermo/Hypersil | B | 1.06 | 0.0330 | 0.0340 | -0.0140 | 0.0950 | 0.0990 | 12.3 | L1 | C18 |
| 756 | Acclaim Mixed-Mode HILIC-1 | Thermo/Hypersil | B | 0.517 | -0.0860 | 0 | 0.126 | 0.0670 | 0.893 | 1.7 | L60 | EP |
| 757 | Acclaim Mixed-Mode WCX-1 | Thermo/Hypersil | B | 0.432 | -0.0990 | -0.606 | 0.168 | -0.156 | 0.990 | 1.5 | L60 | EP |
| 758 | Hypersil ODS | Thermo/Hypersil | B | 0.973 | -0.0510 | -0.0940 | 0.0190 | 1.10 | 0.895 | 5.7 | L1 | C18 |
| 759 | Betasil C8 | Thermo/Hypersil | B | 0.875 | -0.00270 | -0.164 | 0.0310 | 0.0840 | 0.0760 | 8.1 | L7 | C8 |
| 760 | Accucore Biphenyl | Thermo/Hypersil | B | 0.706 | -0.180 | -0.317 | 0.0250 | 0.0770 | 0.727 | 3.3 | L11 | phenyl |
| 761 | YMC-Triart Bio C18 | YMC | B | 0.954 | -0.00810 | -0.139 | 0.0110 | 0.261 | 0.210 | 3 | L1 | C18 |
| 762 | Adamas C18-Select | SepaChrom | B | 0.948 | -0.0660 | 0.422 | 0.00600 | 0.131 | 1.20 | 12.1 | L1 | C18 |
| 763 | Adamas C18-X-Bond | SepaChrom | B | 1.04 | 0.0130 | 0.0950 | -0.0340 | -0.0530 | 0.639 | 12.4 | L1 | C18 |
| 764 | Adamas C18-AQ | SepaChrom | B | 0.847 | -0.0690 | -0.162 | 0.0110 | -0.0670 | 0.664 | 9.3 | L1 | C18 |
| 765 | Adamas C18-Extreme | SepaChrom | B | 1.05 | 0.0220 | -0.0170 | -0.0300 | 0.0370 | 0.167 | 12.7 | L1 | C18 |
| 766 | Adamas C18-Classic | SepaChrom | B | 1.01 | -0.0240 | -0.101 | -0.00100 | 0.0360 | 0.0830 | 12.3 | L1 | C18 |
| 767 | Robusta C18 | SepaChrom | B | 1.06 | -0.00200 | 0.0250 | -0.0250 | -0.0190 | 0.203 | 13.7 | L1 | C18 |
| 768 | Orosil C18-HC | Orochem | B | 1.04 | 0.0130 | 0.128 | -0.0200 | -0.0140 | 0.361 | 14.3 | L1 | C18 |
| 769 | Orosil C18-ER | Orochem | B | 0.907 | -0.0540 | 0.356 | 0.0260 | 0.157 | 1.05 | 10.3 | L1 | C18 |
| 770 | Gazelle C18 | Orochem | B | 1.01 | 0.0180 | 0.0490 | -0.0100 | 0.164 | 0.209 | 11.5 | L1 | C18 |
| 771 | Orosil Polar C18 | Orochem | B | 1.02 | -0.0410 | 0.603 | -0.0170 | 0.291 | 1.37 | 13.1 | L1 | C18 |
| 772 | Agilent 5 Prep C18 Scalar | Agilent Technologies | B | 1.08 | 0.0460 | 0.0840 | -0.0370 | 0.0750 | 0.0180 | 12.6 | L1 | C18 |
| 773 | SunShell Biphenyl | Chromanik | B | 0.775 | -0.110 | -0.330 | -0.00320 | 0.0620 | 0.0870 | 3.76 | L11 | phenyl |
| 774 | SunShell PFP&C18 | Chromanik | B | 0.887 | -0.130 | 0.0130 | -0.0730 | -0.0250 | 1.11 | 5.45 | L11 | phenyl |
| 775 | Sunniest Biphenyl | Chromanik | B | 0.725 | -0.110 | -0.420 | 0.00810 | 0.111 | 0.0590 | 4.33 | L11 | phenyl |
| 776 | Sunniest PFP&C18 | Chromanik | B | 0.857 | -0.120 | -0.0800 | -0.0730 | 0.190 | 1.13 | 7.04 | L11 | phenyl |
| 777 | Halo LPH-C18 | Advanced Materials Technology | B | 0.990 | -0.0360 | 0.330 | 0.00550 | 0.106 | 1.02 | 6.2 | L1 | C18 |
| 778 | Halo 90 A PCS C18 | Advanced Materials Technology | B | 0.933 | 0.00500 | -0.233 | 0.148 | -0.254 | 0.0550 | 5.6 | L1 | C18 |
| 779 | Halo 90 A PCS Phenyl-Hexyl | Advanced Materials Technology | B | 0.663 | -0.0760 | -0.514 | 0.150 | -0.260 | 0.304 | 2.9 | L11 | phenyl |
| 780 | Astra C18-HE | Chromservis | B | 1.02 | -0.00900 | -0.108 | -0.00800 | 0.0370 | 0.144 | 12.7 | L1 | C18 |
| 781 | Astra C18-BDS | Chromservis | B | 0.970 | -0.0220 | -0.0420 | 0.0130 | 0.201 | 0.311 | 6.5 | L1 | C18 |
| 782 | C18-AQ | Chromservis | B | 0.870 | -0.0630 | -0.238 | 0.0100 | -0.0650 | 0.410 | 9.8 | L1 | C18 |
| 783 | Astra Phenyl-Hexyl HE | Chromservis | B | 0.831 | -0.0890 | -0.311 | 0.00400 | 0.0100 | 0.157 | 8.3 | L11 | phenyl |
| 784 | ChromCore C18 | NanoChrom | B | 0.988 | 0.0140 | -0.105 | 0.00600 | 0.213 | 0.173 | 6.6 | L1 | C18 |
| 785 | ChromCore 120 C18 | NanoChrom | B | 0.986 | 0.00400 | -0.110 | -0.00200 | 0.155 | 0.342 | 8.7 | L1 | C18 |
| 786 | ChromCore AQ C18 | NanoChrom | B | 0.975 | 0.00500 | -0.0510 | 0.00800 | 0.193 | 0.208 | 6.2 | L1 | C18 |
| 787 | ChromCore 300 C18 | NanoChrom | B | 0.962 | 0.00500 | -0.116 | 0.0210 | 0.231 | 0.207 | 3.5 | L1 | C18 |
| 788 | ChromCore AR C18 | NanoChrom | B | 0.857 | -0.0760 | 0.281 | 0.0200 | 0.117 | 0.895 | 6.5 | L1 | C18 |
| 789 | ChromCore BR C18 | NanoChrom | B | 0.976 | 0.0370 | -0.0300 | -0.00600 | 0.266 | 0.270 | 4.7 | L1 | C18 |
| 790 | ChromCore 120 C18-T | NanoChrom | B | 0.987 | 0.0290 | 0.210 | -0.0170 | 0.258 | 0.484 | 7.3 | L1 | C18 |
| 791 | ChromCore Polar C18 | NanoChrom | B | 0.824 | 0.0420 | -0.310 | 0.184 | -0.0790 | 0.326 | 6.7 | L1 | C18 |
| 792 | ChromCore T3 | NanoChrom | B | 0.953 | -0.0270 | -0.166 | 0.0190 | 0.173 | 0.142 | 8.2 | L1 | C18 |
| 793 | HALO Elevate C18 | Advanced Materials Technology | B | 1.06 | 0.0230 | -0.0640 | -0.0200 | 0.273 | 0.158 | 4.4 | L1 | C18 |
| 794 | PURITAS 120 C1 | Chromachemie | B | 0.548 | -0.0590 | -0.252 | 0.0190 | -0.0220 | 0.528 | 2.3 | L13 | C1 |
| 795 | PURITAS 120 C4 | Chromachemie | B | 0.701 | -0.0240 | -0.265 | 0.0220 | 0.0720 | 0.282 | 4 | L26 | C4 |
| 796 | PURITAS BIO 300 C4 | Chromachemie | B | 0.787 | -0.0360 | -0.172 | 0.0430 | 0.185 | 0.300 | 2 | L26 | C4 |
| 797 | PURITAS BIO EXIMIUS 300 C8 | Chromachemie | B | 0.819 | -0.00600 | -0.234 | 0.0380 | 0.212 | 0.202 | 2.1 | L7 | C8 |
| 798 | PURITAS EXIMIUS 100 C8 | Chromachemie | B | 0.887 | 0.00600 | -0.159 | 0.0120 | -0.0200 | 0.222 | 9 | L7 | C8 |
| 799 | PURITAS BIO 300 C8 | Chromachemie | B | 0.786 | -0.0330 | -0.168 | 0.0380 | 0.177 | 0.311 | 2 | L7 | C8 |
| 800 | PURITAS PK C8 | Chromachemie | B | 0.880 | 0.0140 | -0.185 | 0.0140 | 0.0590 | 0.0810 | 7.2 | L7 | C8 |
| 801 | PURITAS 120 C8 | Chromachemie | B | 0.820 | -0.0290 | -0.0950 | 0.0190 | 0.0160 | 0.387 | 6.6 | L7 | C8 |
| 802 | PURITAS BIO EXIMIUS 300 C18 | Chromachemie | B | 0.972 | 0.00900 | -0.0950 | 0.0150 | 0.273 | 0.258 | 3.4 | L1 | C18 |
| 803 | PURITAS BIO 300 C18 | Chromachemie | B | 0.929 | -0.0360 | -0.0850 | 0.0310 | 0.250 | 0.322 | 3 | L1 | C18 |
| 804 | PURITAS ODS 120 C18 | Chromachemie | B | 1.00 | -0.00400 | -0.0440 | -0.00300 | 0.112 | 0.243 | 10.2 | L1 | C18 |
| 805 | PURITAS ODS-AQ 120 C18 | Chromachemie | B | 0.943 | -0.0360 | -0.0410 | 0.0100 | 0.0860 | 0.371 | 9 | L1 | C18 |
| 806 | PURITAS PROPREP 200 C18 | Chromachemie | B | 0.951 | -0.0180 | -0.0730 | 0.0180 | 0.220 | 0.284 | 5.6 | L1 | C18 |
| 807 | PURITAS PK C18 | Chromachemie | B | 1.04 | 0.0420 | -0.0140 | -0.0240 | 0.0530 | 0.0290 | 9.9 | L1 | C18 |
| 808 | PURITAS EXIMIUS 100 C18 | Chromachemie | B | 1.07 | 0.0480 | -0.0260 | -0.0280 | -0.142 | -0.0270 | 12.7 | L1 | C18 |
| 809 | PURITAS EXIMIUS 100 C18 | Chromachemie | B | 1.01 | -0.0230 | -0.131 | -0.00800 | -0.110 | 0.128 | 13.5 | L1 | C18 |
| 810 | PURITAS 120 PHENYL | Chromachemie | B | 0.554 | -0.121 | -0.225 | 0.0370 | 0.0600 | 0.763 | 2.5 | L11 | phenyl |
| 811 | Shim-pack Scepter C18-120 | Shimadzu | B | 0.961 | -0.0110 | -0.175 | -0.0300 | 0.00100 | -0.105 | 11.3 | L1 | C18 |
| 812 | Evosphere C12 | Fortis Technologies | B | 1.01 | 0.0110 | 0.0130 | -0.0180 | 0.0800 | 0.232 | 11.9 | L7 | C8 |
| 813 | Evosphere C18/AR | Fortis Technologies | B | 0.904 | -0.0710 | -0.112 | -0.0150 | 0.0590 | 0.832 | 9.24 | L1 | C18 |
| 814 | Evosphere AQUA | Fortis Technologies | B | 1.06 | 0.0130 | 0.490 | -0.0410 | 0.174 | 0.986 | 11.5 | L60 | EP |
| 815 | Evosphere C18/PFP | Fortis Technologies | B | 0.917 | -0.0540 | -0.0830 | -0.0620 | 0.486 | 1.35 | 9.55 | L11 | phenyl |
| 816 | Evosphere PFP | Fortis Technologies | B | 0.740 | -0.113 | -0.183 | -0.0690 | 0.948 | 1.89 | 6.16 | L11 | phenyl |
| 817 | Evosphere RP18 Amide | Fortis Technologies | B | 0.825 | 0.0290 | 0.0620 | 0.196 | -0.772 | 1.35 | 8.59 | L60 | EP |
| 818 | Evosphere Diphenyl | Fortis Technologies | B | 0.654 | -0.176 | -0.361 | 0.0320 | 0.0860 | 1.35 | 4.63 | L11 | phenyl |
| 819 | Caprisil C18-X | Morhchem | B | 1.01 | 0.0300 | -0.0560 | 0.0230 | -0.249 | -0.0260 | 7.03 | L1 | C18 |
| 820 | Caprisil C18-B | Morhchem | B | 1.03 | 0.0280 | -0.0810 | -0.0100 | 0.00400 | -0.0530 | 10.7 | L1 | C18 |
| 821 | Caprisil C18-IP | Morhchem | B | 0.906 | -0.0480 | 0.236 | 0.0350 | 0.194 | 0.776 | 7.61 | L1 | C18 |
| 822 | Caprisil C18-AQ | Morhchem | B | 0.966 | -0.0350 | -0.0420 | 0.0150 | 0.0750 | 0.382 | 9.82 | L60 | EP |
| 823 | Caprisil C18-AQ(2) | Morhchem | B | 0.844 | -0.0750 | -0.0880 | 0.0190 | 0.0240 | 0.698 | 8.95 | L60 | EP |
| 824 | Caprisil C8-P | Morhchem | B | 0.864 | -0.0260 | -0.173 | 0.0200 | 0.0110 | 0.191 | 8.62 | L7 | C8 |
| 825 | Caprisil Phenyl | Morhchem | B | 0.696 | -0.103 | -0.202 | 0.0230 | 0.0140 | 0.604 | 5.51 | L11 | phenyl |
| 826 | Caprisil Hexyl-Phenyl | Morhchem | B | 0.820 | -0.0980 | -0.240 | 0.0120 | 0.0300 | 0.314 | 8.09 | L11 | phenyl |
| 827 | Excsep C18 | OneTwo Chromatography | B | 1.03 | 0.0280 | -0.0780 | 0 | -0.227 | 0.120 | 10.3 | L1 | C18 |
| 828 | Excsep SCB-C18 | OneTwo Chromatography | B | 0.933 | -0.0630 | 0.441 | 0.0300 | 0.115 | 1.02 | 8.27 | L1 | C18 |
| 829 | Excsep HPH-C18 | OneTwo Chromatography | B | 0.955 | -0.00600 | -0.147 | -0.00700 | 0.0380 | 0.111 | 8.02 | L1 | C18 |